• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 ALIGN® URETHRAL SUPPORT SYSTEM RETROPUBIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 ALIGN® URETHRAL SUPPORT SYSTEM RETROPUBIC Back to Search Results
Model Number BRD100R
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Pain (1994); Discomfort (2330)
Type of Reportable Event Serious Injury
Event or Problem Description
The patient's attorney alleged a deficiency against the device.Additional information has been requested, but not yet received.
 
Additional Manufacturer Narrative
The reported event could not be confirmed.No sample was returned for evaluation.Based on the investigation findings, current manufacturing controls are considered adequate as to detect and segregate any non-conforming unit.Event described could not be confirmed as a manufacturing related issue.The alleged event is most likely associated with possible procedural/surgical complications.The ifu currently addresses potential risks associated with surgically implantable materials.Precautions: the usual precautions associated with urological procedures should be followed: accepted surgical practice and precautions must be followed for the management of contaminated or infected wound sites, when the align¿ urethral support system is used.Postoperative retropubic bleeding may occur in some patients and must be controlled prior to patient release.The implant procedure requires diligent attention to anatomical structure and care to avoid puncture of large vessels, nerves, bladder, and any viscera, during introducer needle passage.Cystoscopy should be performed to confirm bladder integrity or recognize a bladder perforation.Proper placement of the mesh sling implant at mid-urethra requires that it lies flat with minimal or no tension under the urethra.The align¿ urethral support system is intended as a single-use, disposable device.Do not resterilize any portion of the align¿ urethral support system.Patients should be advised that pregnancy following a mesh sling implant procedure may negatively affect the success of the previous implant procedure and incontinence may reoccur.The safety and effectiveness of the align¿ urethral support system implant procedure has not been established for the treatment of stress urinary incontinence in males or children under the age of 18.Do not use the align¿ urethral support system if the packaging is opened or damaged.After use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practice and applicable local, state and federal laws and regulations.Adverse events: complications associated with the proper implantation of the align¿ urethral support system may include, but are not limited to: postoperative hematoma, which may occur following the implant procedure temporary urinary retention, bladder outlet obstruction, and voiding difficulties associated with over-correction/too much tension placed on the mesh sling implant perforations or lacerations of vessels, nerves, bladder or any viscera, which may occur during introducer needle passage.Transitory irritation at the operative wound site, which may elicit a foreign body response that leads to inflammation, infection, or erosion of the implant.2348, 1994, 2330="nl".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ALIGN® URETHRAL SUPPORT SYSTEM RETROPUBIC
Common Device Name
ALIGN® URETHRAL SUPPORT SYSTEM RETROPUBIC
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
Manufacturer (Section G)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
Manufacturer Contact
juan velez
8195 industrial blvd
covington, GA 30014
7707846100
MDR Report Key15293028
Report Number1018233-2022-90027
Device Sequence Number2292214
Product Code OTN
UDI-Device Identifier00801741016172
UDI-Public(01)00801741016172
Combination Product (Y/N)N
Initial Reporter StateNJ
Initial Reporter CountryUS
PMA/510(K) Number
K093747
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2008
Reporter Type Manufacturer
Report Source Other
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 08/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date07/30/2008
Device Model NumberBRD100R
Device Catalogue NumberBRD100R
Device Lot NumberCVRIR125
Was Device Available for Evaluation? No
Device Age10 MO
Event Location Hospital
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 08/16/2022
Initial Report FDA Received Date08/25/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured07/12/2007
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexFemale
-
-