ABBOTT VASCULAR SUPERA SELF-EXPANDING STENT SYSTEM; SELF EXPANDING PERIPHERAL STENT SYSTEM Back to Search Results
Model Number S-60-080-120-P6
Medical Device Problem Codes Material Separation (1562); Activation Failure (3270)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/04/2022
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the procedure was to treat the mid right superficial femoral artery (sfa) with moderate calcification.Atherectomy was not used and a 6fr short sheath was used for the procedure.Pre-dilatation was performed with a 6.0x80 mm non-abbott balloon and the 6.0x80 mm supera self expanding stent system (sess) was thought to have deployed the stent.The delivery system was being removed when the tip was noted to have separated.To retrieve the separated tip, the delivery system was removed but the stent was found to have deployed in the sheath.The stent ended up deploying near the femoral access site while the delivery system was pulled out of the anatomy.The separated tip was then retrieved via snare and the deployed stent was removed surgically.A non-abbott stent treated the target lesion.No additional information was provided.
 
Additional Manufacturer Narrative
The device was not returned for analysis.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no other incidents from this lot.As there was no reported damage noted to the device during the inspection prior to use, the investigation determined the reported difficulties appear to be related to circumstances of the procedure as it is likely that during stent deployment the proximal end of the stent inadvertently deployed partially into the introducer sheath resulting in the reported activation/deployment failure.During device removal the tip interacted with the compromised deployed stent ultimately resulting in the reported tip separation.The treatment(s) appears to be related to the operational context of the procedure as the separated tip was then retrieved via snare and the deployed stent was removed surgically.There is no indication of a product quality issue with respect to manufacture, design or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SUPERA SELF-EXPANDING STENT SYSTEM
Common Device Name
SELF EXPANDING PERIPHERAL STENT SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 2024168
26531 ynez road
temecula CA 92591 4628
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key15312620
Report Number2024168-2022-09214
Device Sequence Number2786269
Product Code NIP
UDI-Device Identifier08717648211812
UDI-Public08717648211812
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
P120020
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Device Explanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 08/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/31/2024
Device Model NumberS-60-080-120-P6
Device Catalogue NumberS-60-080-120-P6
Device Lot Number2020361
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 08/05/2022
Initial Report FDA Received Date08/29/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured02/03/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
6FR SHORT SHEATH; TREASURE18 300CM
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-