MAUDE Adverse Event Report: ABBOTT VASCULAR XIENCE SKYPOINT DRUG ELUTING CORONARY STENT DELIVERY SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT VASCULAR XIENCE SKYPOINT DRUG ELUTING CORONARY STENT DELIVERY SYSTEM Back to Search Results
Model Number 1804400-38
Medical Device Problem Codes Difficult to Insert (1316); Stretched (1601); Improper or Incorrect Procedure or Method (2017); Failure to Advance (2524)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/06/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the procedure was to treat a moderately calcified, moderately tortuous, 90% stenosed lesion in the distal right coronary artery (drca).A 4x38mm xience skypoint drug eluting stent (des) was advanced in a 6f guide catheter (gc) but could not reach the target lesion due to the anatomy.The des and 6f gc were removed and a 7f gc was then positioned.During re-insertion onto the guide wire, the tip of the des was noted to be stretched by approximately 2 centimeters (cm) and could not be inserted onto the guide wire (gw), so the tip of the des was cut and then was able to be inserted onto the gw, advanced to the target lesion and the stent implanted to successfully complete the procedure.There was no adverse patient effect and no clinically significant delay in the procedure.Returned device analysis noted that the inner member was stretched proximal to the distal tapered portion of the balloon.No additional information was provided.
 
Additional Manufacturer Narrative
Visual and functional inspections were performed on the returned device.The reported stretched tip was confirmed.The reported failure to advance could not be tested as it was based on operational context.The reported difficult to insert could not be tested due to the device condition.Additionally, it was noted that the inner member was stretched proximal to the distal tapered portion of the balloon.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history of the reported lot did not indicate a lot specific quality issue.It was reported that the stent delivery system (sds) was used in a procedure after damage to the tip was observed.It should be noted that the xience skypoint instructions for use (ifu) states not to use the stent delivery system if any defects are noted.It is unknown if the ifu deviation directly caused or contributed to the reported event the investigation determined the reported difficulties appear to be related to the operational context of the procedure.In this case, it is likely that the stent delivery system (sds) interacted with the moderately calcified, moderately tortuous, and 90% stenosed lesion during advancement, resulting in the reported failure to advance.Manipulation of the device during its interaction with the challenging anatomy likely contributed to the noted stretched inner member and reported stretched tip.The stretched tip likely resulted in the reported difficult to insert over the guide wire.There is no indication of a product quality issue with respect to manufacture, design, or labeling.
 
Additional Manufacturer Narrative
It was reported that the stent delivery system (sds) was inserted into the anatomy, removed, and then reinserted.It should be noted that the xience skypoint instructions for use (ifu) states an unexpanded stent may be retracted into the guiding catheter one time only.An unexpanded stent should not be reintroduced into the artery once it has been pulled back into the guiding catheter.The investigation determined the reported failure to advance appears to be related to the operational context of the procedure; however, the investigation was unable to determine a conclusive cause for the reported stretched tip.In this case, it is likely that the stent delivery system (sds) interacted with the moderately calcified, moderately tortuous, and 90% stenosed lesion during advancement, resulting in the reported failure to advance.Additionally, factors that may contribute to stretched tip include, but are not limited to, interaction with the guiding catheter, interaction with the guide wire, entrapment of the tip, or manipulation of the tip.Based on the information provided and the condition of the returned device, it is unknown what may have caused the reported stretched tip and noted stretched inner member.There is no indication of a product quality issue with respect to manufacture, design, or labeling; therefore, no product-related corrective action will be implemented in this case.B1 - adverse event/product problem updated from "adverse event, product problem" to "product problem".H6 - medical device problem code 1316 - removed.H10 - addtl mfg narrative: revised.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XIENCE SKYPOINT DRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Common Device Name
DRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005718570 (P099)
cashel road
clonmel tipperary
EI  
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key15322740
Report Number2024168-2022-09257
Device Sequence Number20156856
Product Code NIQ
UDI-Device Identifier08717648233524
UDI-Public08717648233524
Combination Product (Y/N)Y
Initial Reporter CountryJA
PMA/510(K) Number
P110019
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/16/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/09/2023
Device Model Number1804400-38
Device Catalogue Number1804400-38
Device Lot Number0090341
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/16/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 08/09/2022
Supplement Date Received by Manufacturer09/13/2022
Initial Report FDA Received Date08/30/2022
Supplement Report FDA Received Date09/16/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/10/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
6F GUIDE CATHETER; GUIDE PLUS
Patient Age75 YR
Patient SexMale
Patient Weight68 KG
-
-