MAUDE Adverse Event Report: ZIMMER BIOMET, INC. TIBIAL COMPONENT PRECOAT RIGHT MEDIAL/LEFT LATERAL SIZE 4; PROSTHESIS, KNEE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER BIOMET, INC. TIBIAL COMPONENT PRECOAT RIGHT MEDIAL/LEFT LATERAL SIZE 4; PROSTHESIS, KNEE Back to Search Results
Model Number 5842-04-02
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Pain (1994); Synovitis (2094); Swelling/ Edema (4577)
Date of Event 10/16/2020
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a patient underwent a left knee procedure.Subsequently, for two years post implantation, the patient has had persistent and ongoing pain, swelling, and difficulty with daily activities.The patient experiences a scraping sensation and sharp focal pain when the knee is bent past 90 degrees.At one year post implantation, two ultrasounds were completed which suggested synovitis and degenerative changes affecting the iliotibial band and the lateral collateral ligament.Medical evaluations and extensive rehabilitation have not improved symptoms and imaging studies reportedly show severe irritation to the lateral collateral ligament at the location of the implanted components.At this time, no further medical intervention has been reported and the products remain implanted.
 
Additional Manufacturer Narrative
(b)(4).Medical product: articular surface size 4 8 mm height femoral size a,b,c,d,e,f,g: catalog#00584202408, lot#64500538; femoral component high flex precoat for cemented use only right medial/left lateral: catalog#00584201502, lot#64654549; palacos fast r+g 1x40: catalog#66056768, lot#95434925.Report source: foreign: australia.Multiple mdr reports have been filed for this event.Please see associated reports: 0001822565-2022-02495; 0001822565-2022-02496.Visual and dimensional evaluations could not be performed as no product was returned.Photograph provided shows that the left knee is swollen.Device history record was reviewed and no discrepancies related to the reported event were found.Medical records were provided and reviewed by a health care professional.Review of the available records identified the following: patient xray and ultrasound show severe irritation to lcl, multiple orthopedic evaluations, patient is lean and fit at baseline.Root cause was unable to be determined.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TIBIAL COMPONENT PRECOAT RIGHT MEDIAL/LEFT LATERAL SIZE 4
Common Device Name
PROSTHESIS, KNEE
Manufacturer (Section D)
ZIMMER BIOMET, INC.
1800 w. center st.
warsaw IN 46580
Manufacturer (Section G)
ZIMMER BIOMET, INC.
1800 w. center st.
warsaw IN 46580
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key15327610
Report Number0001822565-2022-02494
Device Sequence Number20423294
Product Code HSX
UDI-Device Identifier00889024193659
UDI-Public(01)00889024193659(17)271031(10)63838877
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K033363
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Consumer,Health Professional
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 08/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number5842-04-02
Device Catalogue Number00584200402
Device Lot Number63838877
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/10/2022
Initial Report FDA Received Date08/31/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured11/03/2017
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age32 YR
Patient SexMale
Patient Weight70 KG
-
-