MAUDE Adverse Event Report: TELEFLEX MEDICAL EZ-IO POWER DRIVER; NEEDLE, HYPODERMIC, SINGLE LU

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TELEFLEX MEDICAL EZ-IO POWER DRIVER; NEEDLE, HYPODERMIC, SINGLE LU Back to Search Results
Model Number IPN915667
Medical Device Problem Code Complete Loss of Power (4015)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/01/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The device investigation is pending.
 
Event or Problem Description
Driver bogged down on use of a patient.They were unsuccessful with placing manual insertion and the user was not sure the patient outcome.
 
Event or Problem Description
Driver bogged down on use of a patient.They were unsuccessful with placing manual insertion and the user was not sure the patient outcome.
 
Additional Manufacturer Narrative
(b)(4).The manufacturing dhr file was reviewed.It was revealed that during one test "test - fct" the result was "automatic fail".However, 3 additional attempts were completed , and the result was "pass" in each successive attempt.Therefore, the unit must have met all requirements for release.Ez-io driver 9058 (sn (b)(6)) was returned for evaluation.Upon receipt, the driver was visually inspected.There were small black marks observed on the driver which is the result of normal use.When the trigger was pulled, the driver was operable , and a solid green led light was displaying.The led was not flashing green as reported.The driver was then subjected to simulated sawbone insertions per driver ifu.This functional test is used to determine whether the returned device still has the capability to power a 45mm ez-io needle set into a medium and/or hard bone.The 45mm ez-io needle set is used because it represents the worst-case scenario for io insertion.Two (2) sawbones with medium (50 lbs/ft 3) and hard (105 lbs/ft 3) hardness profiles with 3mm cortexes were used for the test.Each insertion was timed with a stopwatch (id: ref-003150) while applying approximately 8 lbs.Of force on a weight scale (id: ref-002481).Approximately 5 to 8 lbs.Of force is necessary to penetrate bone.Below are the test results: the driver successfully negotiated both the medium and hard saw bone insertion testing.The complaint cannot be confirmed.The driver was opened to test and record operating characteristics.Battery voltage measured as 17.64 dc volts (voltmeter: ref-002629) without being activated.Battery voltage measured as 14.91 dc volts when button was activated , and voltage reached a stable level.Stable defined as when whole numbers (e.G., 6 volts, 7 volts, etc.) stop changing (ignoring numbers after the decimal point).The measured voltage is slightly lower than the nominal specification of 18.2v for the battery pack upon release.This is expected after device use.The eeprom was parsed , and the results reveal the charge count was 5,063,518 and the cycle count was 636.The cycle count of 636 (trigger activations) is significant as it substantiates driver usage with considerations to bone density, average insertion time, storage, and frequency of testing.The eeprom results confirm that the battery is not depleted as the charge count has not exceeded the maximum depletion value of 15,300.Additionally, 4 stall conditions were recorded.The stall conditions may be the result of excess downward pressure on the driver during use.Testing confirms that there was no fault found with the returned driver.Two ifus will be referenced for this investigation.The ez-io driver ifu (8048a rev.04) states, "as with any emergency medical device carrying a backup is strongly advised protocol", "ez-io power driver led will blink red when the trigger is activated and has only 10% of battery life remaining".The ez-io needle ifu states, "squeeze trigger and apply gentle, steady pressure.Important: do not use excessive force.Note: if ez-io power driver stalls and ez-io needle set will not penetrate the bone, operator may be applying too much downward pressure to penetrate bone." a review of the device history record found that the driver passed all the release criteria.The device was released in 11/2017 and is approximately 5 years old.In summary, the complaint cannot be confirmed.Functional testing revealed no fault found with this driver as the device was able to negotiate both the medium and hard saw bones during insertion testing.No defects or anomalies were observed with the returned driver.A device history record review was performed , and no recorded results of manufacturing issues or anomalies were reported.Teleflex will continue to monitor and trend on complaints of this nature.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EZ-IO POWER DRIVER
Common Device Name
NEEDLE, HYPODERMIC, SINGLE LU
Manufacturer (Section D)
TELEFLEX MEDICAL
athlone
Manufacturer (Section G)
TELEFLEX MEDICAL
3015 carrington mill blvd
morrisville NC 27560
Manufacturer Contact
jasmine brown
3015 carrington mill blvd
morrisville, NC 27560
9193614124
MDR Report Key15363019
Report Number3011137372-2022-00183
Device Sequence Number17752165
Product Code FMI
UDI-Device Identifier10816000013813
UDI-Public10816000013813
Combination Product (Y/N)N
Initial Reporter StateMO
Initial Reporter CountryUS
PMA/510(K) Number
K180395
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 08/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberIPN915667
Device Catalogue Number9058
Device Lot NumberJ60524
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/29/2022
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/25/2022
Supplement Date Received by Manufacturer10/12/2022
Initial Report FDA Received Date09/06/2022
Supplement Report FDA Received Date10/13/2022
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device A
Patient Sequence Number1
Patient SexUnknown
-
-