|
Product complaint # (b)(4).This is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Trade name - irgacare®, active ingredient(s) ¿ triclosan, dosage form ¿ suture/solid/parenteral, strength ¿ = 2360 g/m.(b)(4).Device not returned.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Additional information was requested, and the following was obtained: on what tissue was the suture used/location of suture placement? subcuticular what tissue dehisced? surgeon said there was a gap and he used a interrupted suture for closure in clinic.Size of dehiscence? unknown.What was the tissue condition (normal, thin, calcified, fragile, diseased)? unknown.How was the suture placed (interrupted or continuous)? interrupted.How was the suture tied (square knot or multiple knots one end)? stratafix - no knots.Onset date/time of dehiscence? (# post op days) first week post op.How was the dehiscence managed? interrupted suture, prophylactic antibiotics.Please describe any surgical intervention required for the wound dehiscence including date and findings.- unknown.Please describe the appearance of the suture during the second procedure.- unknown.Were there any precipitating stress factors for the sutures untying, breakage or pulling out of the tissue? unknown.Did the operating surgeon observe any suture deficiency or anomaly before, during, after the suture placement and did the operating surgeon observed any suture deficiency or anomaly before, during, after the suture placement and during any re operation? unknown.Lot number? unknown.Provide the specific number of patient events: unknown.Did the event occur during one or multiple patient procedures? multiple.What is the total number of procedures? unknown.Have any of these events been previously reported to ethicon? if so, provide the respective reference number(s).No.If this event occurred in multiple procedures, please provide information requested above for each patient event.What are the procedure name(s) and date(s)? unknown.What is the quantity involved per procedure.Unknown.Was there any adverse patient consequence(s) or subsequent medical/surgical intervention? no.The single complaint was reported with multiple events.There are no additional details regarding the additional events.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Was the fixation loop secured to tissue at the initiation of suture use during the index procedure? was at least one reverse stitch performed prior to closure? did the stratafix suture break? if so, where was the break noted (termination, middle, end)? what is the physician¿s opinion as to the etiology of or contributing factors to this event? what is the patient's current status?.
|
|
(b)(4).Date sent to the fda: 9/28/2022.This is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Additional information: b1 product problem.Additional information was requested and the following was obtained: was the fixation loop secured to tissue at the initiation of suture use during the index procedure? unknown.Was at least one reverse stitch performed prior to closure? yes.Did the stratafix suture break? if so, where was the break noted (termination, middle, end)? middle.What is the physician¿s opinion as to the etiology of or contributing factors to this event? unknown.What is the patient's current status? physician said patients are fine (b)(4).Corrected information: h6 medical device problem code.
|