| Model Number |
SXPD2B420 |
| Health Effect - Clinical Code |
Wound Dehiscence (1154)
|
| Date of Event |
06/16/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
A batch review of the finished good lot and components confirmed there were no quality issues noted throughout the incoming inspection, manufacturing, sterilization, in-process, or final inspection process.No samples were returned for review.No photos of the device or the surgical sites were provided for review.If samples or photos become available at a later time, they will be reviewed, tested and the details will be included as part of the investigation file and a follow-up report will be submitted at that time.¿adverse events including wound dehiscence and reactions are common risks/complications of any surgical procedure.There are many causes that can result in the wound opening, sutures failing or reaction, infection, abscess/leakage during or post-operative a procedure: the patient¿s health status, poor skin quality, thin skin; the risk is higher with a patient with a weak immune system, malnutrition, or chronic medical condition.The surgical procedure ¿ the risk increases with poor surgical techniques such as improper suturing, over-tightened sutures or inappropriate type of suture used for a particular procedure.Other factors - the risk is greater with smoking, obesity, premature post-surgery exercise and heavy lifting.The warning section in the ifu states, ¿this an absorbable material, the use of supplemental non absorbable sutures should be considered by the surgeon in the closure of sites which may undergo expansion, stretching or distention or which may require additional support¿.Without receiving sterile samples from the same lot to review/test, receiving photos of the suture/incision(s) post-operative, or receiving detailed information regarding the pre-operative preparation of the device, procedure(s) performed, placement of the suture in the tissue, method of anchoring the device in the tissue, post-operative activities or events that may have occurred or the surgeon¿s technique, a definitive root cause cannot be determined at this time.
|
| |
|
Event or Problem Description
|
|
Per user facility medwatch # mw5111556 during a spinal procedure it was reported by healthcare professional: ¿wound dehiscence after use of ethicon stratafix required the patient to return to surgery.¿ this event occurred in five (5) episodes/patients.The device is not available for return.
|
| |
|
Additional Manufacturer Narrative
|
|
A batch review of the finished good lot and components confirmed there were no quality issues noted throughout the incoming inspection, manufacturing, sterilization, in-process, or final inspection process.No sterile samples were returned for review.If samples or photos become available at a later time, they will be reviewed, tested and the details will be included as part of the investigation file.An opened device was returned with the foil pouch labeled as lot number aaib068.The needle/suture device appeared used (ex.Blood, engaged barbs).There was no damage observed on the needle.The one (1) needle remained securely attached to the suture when gently tugged during the analysis.There was slight damage to the suture directly at the attachment; the suture appeared to have teeth marks from being grasped by the needle holder.The barbs along the strand were engaged; no unusual damage observed.The end point of failure appeared smooth, slightly flared, possibly cut by a sharp surgical instrument.The characteristics observed on this sample appear to indicate that the sample was cut during use.The other part of the device, other needle was not returned for review.The problem reported was dehiscence post-operative.The needle would not remain attached to a suture removed from tissue post-operative; from a patient returning with a dehisced incision.¿adverse events including wound dehiscence and reactions are common risks/complications of any surgical procedure.There are many causes that can result in the wound opening, sutures failing or reaction, infection, abscess/leakage during or post-operative a procedure: the patient¿s health status, poor skin quality, thin skin; the risk is higher with a patient with a weak immune system, malnutrition, or chronic medical condition.The surgical procedure ¿ the risk increases with poor surgical techniques such as improper suturing, over-tightened sutures or inappropriate type of suture used for a particular procedure.Other factors - the risk is greater with smoking, obesity, premature post-surgery exercise and heavy lifting.The warning section in the ifu states, ¿this an absorbable material, the use of supplemental non absorbable sutures should be considered by the surgeon in the closure of sites which may undergo expansion, stretching or distention or which may require additional support¿.Without receiving sterile samples from the same lot to review/test, receiving photos of the suture/incision(s) post-operative, or receiving detailed information regarding the pre-operative preparation of the device, procedure(s) performed, placement of the suture in the tissue, patient¿s health history or quality of the tissue where material was placed, method of anchoring the device in the tissue, post-operative activities or events that may have occurred that attributed to the adverse event or the surgeon¿s technique, a definitive root cause cannot be determined at this time.
|
| |
|
Search Alerts/Recalls
|
|