| Model Number |
A319516AM |
| Medical Device Problem Code |
Component Missing (2306)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
08/26/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.Section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported that there was no catheter in foley tray that connected to drainage tube.
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event was inconclusive, and it is unknown whether the device had met relevant specifications.The product was not used for patient treatment.It was unknown whether the product had caused the reported failure.Although a specific cause cannot be determined, based on the risk document a potential root cause for this event could be ¿incorrect operation".The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: "bard® ez-lok® sampling port(indicated by the blue stem in the port) accepts luer lock or slip tip syringes 1.Occlude drainage tubing a minimum of 3 inches below the sampling port by kinking the tubing until urine is visible under the access site.2.Swab surface of bard® ez-lok®sampling port with antiseptic wipe.3.Using aseptic technique,position the syringe in the center of the sampling port.Press the syringe firmly and twist gently to access the sampling port.4.Slowly aspirate urine sample into syringe and remove syringe from sample port.5.Unkink tubing if necessary and transfer urine specimen into specimen cup or follow hospital protocol.Discard syringe according to hospital protocol.6.Follow established hospital protocol for specimen labeling and transport to lab." h11: section a through f - the information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
|
| |
|
Event or Problem Description
|
|
It was reported that there was no catheter in foley tray that connected to drainage tube.Per additional information received via sample form on (b)(6) 2022, customer stated that box opened and part was missing.
|
| |
|