SMITHS MEDICAL INTERNATIONAL, LTD. PNEUPAC VENTILATORS PARAPAC PLUS; VENTILATOR, EMERGENCY, POWERED (RESUSCITATOR) Back to Search Results
Model Number P300NUS
Medical Device Problem Codes Device Alarm System (1012); Inaccurate Flow Rate (1249)
Health Effect - Clinical Codes Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/15/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the device will not end the breath.Keeps pumping and pushing air.Low battery alarm.There has been no report of patient involvement or no observable clinical symptoms or a change in symptoms identified in the patient.
 
Additional Manufacturer Narrative
No information has been provided to date.A product sample was received and is awaiting evaluation and investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.
 
Additional Manufacturer Narrative
Other, other text: the date of event was 15aug2022.(updated b5 and b3).A product sample was received and is awaiting evaluation and investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.
 
Event or Problem Description
Additional information was received via email on 12-sep-2022.The event date was updated.Unknown if patient was involved.
 
Additional Manufacturer Narrative
Other text: h3.Device evaluated by manufacturer and h6.Health impact, and evaluation codes: updated.One device was received with slight impact marks on the housing at the bottom right and top left.Continuous cycling was present.Unable to duplicate low battery alarm.The complaint was confirmed.A root cause could not be determined as the continuous flow was intermittent.The product's history records were reviewed and there were no non-conformances nor service-related issues that would have resulted in the reported complaint.The regulator and timing valve assembly were replaced.Device passed all functional and delivery tests., corrected data: h6 health effects - clinical signs and symptoms or conditions.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PNEUPAC VENTILATORS PARAPAC PLUS
Common Device Name
VENTILATOR, EMERGENCY, POWERED (RESUSCITATOR)
Manufacturer (Section D)
SMITHS MEDICAL INTERNATIONAL, LTD.
bramingham business park, enterprise way
luton, bedforshire LU3 4 BU
UK  LU3 4BU
Manufacturer (Section G)
NULL
bramingham business park, enterprise way
luton, bedforshire LU3 4 BU
UK   LU3 4BU
Manufacturer Contact
jim vegel
6000 nathan lane north
minneapolis, MN 55442
MDR Report Key15401974
Report Number3012307300-2022-18675
Device Sequence Number6179029
Product Code BTL
UDI-Device Identifier35019315107270
UDI-Public35019315107270
Combination Product (Y/N)N
Initial Reporter StateNV
Initial Reporter CountryUS
PMA/510(K) Number
K123957
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/16/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model NumberP300NUS
Device Catalogue NumberP300NUS
Was Device Available for Evaluation? No
Date Returned to Manufacturer08/22/2022
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/15/2022
Supplement Date Received by Manufacturer09/12/2022
09/29/2023
Initial Report FDA Received Date09/12/2022
Supplement Report FDA Received Date10/07/2022
10/16/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured02/09/2022
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-