| Model Number |
TRULIANT TIB IMP CRC INSERT SZ 3.5, 9MM |
| Medical Device Problem Codes |
Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Codes |
Pain (1994); Implant Pain (4561)
|
| Date of Event |
08/15/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
No device return anticipated as it is not available.Concomitant medical products: 02-020-14-0335 - truliant cr por fem cr por right sz 3.5 sn: (b)(4), 02-022-55-3525 - truliant por tib tray size 3.5f/2.5t sn: (b)(4), 201-78-15 - holding pin mini sharp point 4 pk sn: (b)(4), 521-78-23 - threaded pin size 2.3 collared 2pk sn: (b)(4), 521-78-32 - threaded pin size 3.0 collarless 2pk sn: (b)(4), 521-78-32 - threaded pin size 3.0 collarless 2pk sn: (b)(4), 521-78-36 - threaded pin size 5.1 collarless 2pk sn: (b)(4), a10012 - gps implant kit v2 10042320077.Additional information, including the product investigation, will be submitted within 30 days of receipt.
|
| |
|
Event or Problem Description
|
|
It was reported that a female patient, initially implanted on the right knee on (b)(6) 2020, underwent a revision due to pain.The surgeon removed the insert and stated there was no significant poly wear.The articulation surface appeared smooth with no damage.The original insert was 9mm but the 10mm trial was found to be stable with good rom so a new 10mm crc was implanted.The surgeon also resurfaced the patella with a standard 35mm 3 peg patella and stated that the patient¿s pain was possibly from the patella.Patient was last known to be in stable condition following the event.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: based on review of all available information, there is no evidence to suggest that the reported event is related to any design issues.The cause of the subsequent revision cannot be conclusively determined; however, it is most likely related to the patient¿s condition.
|
| |
|
Event or Problem Description
|
|
Additional information: no issues.Explants never available due to hospital policy".There were no reported issues with the revision surgical procedure.No additional information.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay corrected information.The following sections were corrected: b1, b2, g2, h6: clinical code, medical device problem code, component code, type of investigation, investigation finding, investigation conclusion.Based on review of all available information, there is no evidence to suggest that the reported event is related to any design issues.The cause of the subsequent revision cannot be conclusively determined; however, it is most likely related to the patient¿s condition.These devices are used for treatment not diagnosis.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|