It was reported that there was an alleged potential for death; however, the actual issue is unknown.Pulled from health canada¿s medical devices online databases.As per follow-up information received on 30aug2022, foley catheter did not drain for 6hours and urine was noted to be bypassing.The user attempted to deflate balloon to remove from bladder which was unable to do so.The catheter clamped to detach when balloon popped inside bladder and the patient felt pain.Catheter was removed with piece of silicone that made up balloon missing.Cystoscopy had been ordered in order to remove piece of silicone from patient's bladder to prevent sepsis.
|
|
It was reported that there was an alleged potential for death; however, the actual issue is unknown.Pulled from health canada¿s medical devices online databases.As per follow-up information received on 30aug2022, foley catheter did not drain for 6hours and urine was noted to be bypassing.The user attempted to deflate balloon to remove from bladder which was unable to do so.The catheter clamped to detach when balloon popped inside bladder and the patient felt pain.Catheter was removed with piece of silicone that made up balloon missing.Cystoscopy had been ordered in order to remove piece of silicone from patient's bladder to prevent sepsis.
|
|
The reported event was inconclusive because no sample was returned.It is unknown whether the device had met relevant specifications.The product was used for urological care.It was unknown whether the product had caused the reported failure.The potential root cause for this failure could be user related (example: over aspirated, incorrect syringe/collapse lumen/sac close eye/valve damage).A dhr review is not required as the lot number is unknown.Therefore, no additional action required at this time.The device was not returned for evaluation.The lot number is unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: warning: do not use ointments or lubricants having a petrolatum base.They will damage latex.Visually inspect the product for any imperfections or surface deterioration prior to use.Use luer tip syringe to inflate with stated ml of sterile water.Or for pre-filled products, remove clip and squeeze reservoir to inflate with stated ml of sterile water.For urological use only.To deflate catheter balloon: gently insert a luer slip tip syringe in the catheter valve.Never use more force than is required to make the syringe ¿stick¿ in the valve.Allow the pressure within the balloon to force the plunger back and fill the syringe with water.If you notice slow or no deflation, re-seat the syringe gently.Use only gentle aspiration to encourage deflation if needed.Vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.If necessary, contact adequately trained professional for assistance, as directed by hospital protocol.Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient.This is a single use device.Do not resterilize any portion of this device.Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patient.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text: the device was not returned.
|