Patient allegedly received an implant on (b)(6) 2012 via the right internal jugular vein due to deep vein thrombosis (dvt).Patient is alleging mesenteric perforation, and tilt.Patient further alleges "stress and worry of the filter still being inside of me and what could happen." "i can no longer do heavy lifting or long walking, not sure if it is related to filter or not." per computed tomography report, "a tent shaped inferior vena cava filter is identified in place with head located 3.5 cm below the level of the right renal vein level (the lowest vein).It has a long axis parallel to the long axis of the inferior vena cava on the sagittal and coronal projections.The filter has 4 interconnected peripheral struts demonstrating mild tenting of the ivc wall consistent with grade 1 perforation.No fracture or deformity of the filter is identified.The inferior vena cava above and below that level is of normal caliber.".
|
|
The previous medwatch report was submitted by william cook europe under manufacturer report reference# 3002808486-2022-00901.Additional information provided determined that this device was manufactured by cook inc.With the submission of this initial medwatch report, cook inc.Informs that all future submissions regarding this complaint will be handled under the manufacturer report reference # referenced in g8 of this initial medwatch report.Investigation is reopened due to additional information provided.The following allegations have been investigated: organ perforation, tilt, stress, worry, limited physical ability.The reported allegations have been further investigated based on the information provided to date.Filter interacts with ivc wall, e.G.Penetration/perforation/embedment.This may be either symptomatic or asymptomatic.Potential causes may include improper deployment; and (or) excessive force or manipulations near an in-situ filter (e.G., a surgical or endovascular procedure in the vicinity of a filter).Potential adverse events that may occur include, but are not limited to, the following: trauma to adjacent structures, vascular trauma.Filter tilt has been reported.Potential causes may include filter placement in ivcs with diameters larger than those specified in these instructions for use; improper deployment; manipulations near an implanted filter (e.G., a surgical or endovascular procedure in the vicinity of a filter); and (or) a failed retrieval attempt.Excessive filter tilt may contribute to difficult or failed retrieval; vena cava wall penetration/perforation; and (or) result in loss of filter efficiency.Potential adverse events that may occur include, but are not limited to, the following: unacceptable filter tilt.Unknown if the reported stress, worry, and limited physical ability are directly related to the filter and unable to identify a corresponding failure mode at this point in time.A total of (b)(4) devices were manufactured in the reported lot.To date, no other complaints have been reported against the lot.The associated work order was reviewed.No related/relevant notes were documented.The device is manufactured and inspected according to specifications.No evidence to suggest that this device was not manufactured according to specifications and nothing indicates that the filter did not perform as intended, e.G.Intended for the prevention of recurrent pulmonary embolism (pe) via placement in the vena cava.Cook will reopen its investigation if further information is received warranting supplementation in accordance with 21 c.F.R.803.56.This report includes information known at this time.A follow-up medwatch report will be submitted if additional relevant information become available.This report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, or that any cook device caused or contributed to or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|