Model Number 42-5282-006-10
Medical Device Problem Code Difficult to Insert (1316)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/23/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Medical product: partial tibial cemented size f right medial: catalog#42538000602, lot#64087092.Foreign: (b)(6).Customer has indicated that the product is in process of being returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event or Problem Description
It was reported that during an initial partial knee arthroplasty, the articular surface would not seat with the tibial tray.A second bearing was used and the procedure was completed without complication.There was no surgical delay nor patient impact.Attempts have been made and no further information has been provided.
 
Additional Manufacturer Narrative
The investigation is in progress.Upon completion of the investigation or receipt of additional information, a follow-up mdr will be submitted.
 
Event or Problem Description
No further event information at time of this report.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional information.Visual inspection of the returned articular surface exhibits damage to the locking feature.Damage includes being nicked or gouged and a crack in the locking feature on the medial/anterior location.The locking feature is nicked, gouged and compressed.Shows that the locking features are compressed.Device history record was reviewed and no discrepancies related to the reported event were found.Investigation results concluded that the reported event is attributed to use error.Detailed instructions for inserting the articular surface are provided in the associated surgical technique.Damage to the articular surface can occur if the articular surface is not correctly placed and oriented before pushing it with the inserter instrument.A summary of the investigation was sent to the complainant conveying proper surgical technique and use of the device.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event or Problem Description
No further event information at time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PARTIAL ARTICULAR SURFACE RIGHT MEDIAL SIZE F 10 MM THICKNESS
Common Device Name
PROSTHESIS, KNEE
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer (Section G)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key15432387
Report Number0001825034-2022-02151
Device Sequence Number5673664
Product Code HSX
UDI-Device Identifier00880304818378
UDI-Public(01)00880304818378(17)221231(10)63887333
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K161592
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 02/02/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/31/2022
Device Model Number42-5282-006-10
Device Catalogue Number42528200610
Device Lot Number63887333
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/25/2022
Supplement Date Received by Manufacturer09/20/2022
02/01/2023
Initial Report FDA Received Date09/15/2022
Supplement Report FDA Received Date09/27/2022
02/03/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/11/2018
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexPrefer Not To Disclose
-
-