MAUDE Adverse Event Report: EDWARDS LIFESCIENCES EDWARDS SAPIEN XT; PROSTHESIS, MITRAL VALVE, PERCUTANEOUSLY DELIVERED

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

EDWARDS LIFESCIENCES EDWARDS SAPIEN XT; PROSTHESIS, MITRAL VALVE, PERCUTANEOUSLY DELIVERED Back to Search Results
Model Number 9300TFX
Device Problem Degraded (1153)
Patient Problem Insufficient Information (4580)
Event Date 08/26/2022
Event Type  Injury  
Manufacturer Narrative
Investigation is ongoing.Device information not provided.Device remains implanted.
 
Event Description
As reported by a field clinical specialist, a patient underwent a successful thv-in-thv procedure with a 23mm sapien 3 ultra valve inside a previous 26mm sapien xt valve in the mitral position.The valve-in-valve procedure is due to the stenosis of the sapien xt valve.
 
Manufacturer Narrative
A supplemental mdr is being submitted due to engineering evaluation findings.Sections b4, g3, g6, h2, h6: type of investigation, investigation findings, investigation conclusions and h10 has been updated.The device was not returned to edwards lifesciences for evaluation.A review of edwards lifesciences risk management documentation was performed for this case.The reported event is an anticipated risk of the transcatheter heart valve procedure, additional assessment of this event is not required at this time.The complaint for valve degeneration-deterioration was confirmed based on medical records provided for evaluation.The reported event does not allege a malfunction that could be related to an edwards manufacturing deficiency.A review of the ifu and training manuals also revealed no deficiencies.It should be noted that this was an off-label operation as the thv was implanted in mitral position within pre-existing thv, which was not an indicated use of the sapien xt with the ascendra+ delivery system (ds).During the manufacturing process, all sapien xt valves are 100% visually inspected for defects and 100% tested for proper coaptation under physiological backpressure conditions prior to release for distribution.Therefore, it is highly unlikely that a manufacturing defect or device malfunction contributed to the event.As reported, -a patient underwent a successful thv-in-thv procedure with a 23mm sapien 3 ultra valve inside a previous 26mm sapien xt valve in the mitral position.The valve-in-valve procedure is due to the stenosis of the sapien xt valve.- per the instructions for use (ifu), structural valve deterioration (wear, fracture, calcification, leaflet tear/tearing from the stent posts, leaflet retraction, suture line disruption of components of a prosthetic valve, thickening, stenosis), and device degeneration are listed in the instructions for use for the thv procedure and are known potential risks associated with the device.Structural valve deterioration (svd) may be manifested as stenosis with thickened leaflets.Svd refers to changes intrinsic to the valve and can include failure modes such as wear, calcification, leaflet tear, stent creep, leaflet disruption, or leaflet retraction.Svd may be mild and not require any intervention or it may be moderate to severe.It can cause the heart to work harder to eject blood from the ventricle.Depending on the severity it could be an indication for valve replacement or medical intervention.Tissue calcification is a very common failure mode.The mechanisms for bioprosthetic heart valve tissue calcification are not yet fully understood.Many factors can contribute to the onset and propagation of calcification including patient-related (e.G.Patient age, disease state, immune status, and other co-morbidities), pharmacological, and intrinsic properties of the valve itself.It is widely understood that patients with chronic renal disease and prior history of calcific stenosis of the native valve may be predisposed to bioprosthetic calcification.In this case, due to insufficient information, a definitive root cause was unable to be determined.No ifu/labeling/training manual inadequacies were identified.Therefore, no corrective or preventative action nor pra is required at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EDWARDS SAPIEN XT
Type of Device
PROSTHESIS, MITRAL VALVE, PERCUTANEOUSLY DELIVERED
Manufacturer (Section D)
EDWARDS LIFESCIENCES
1 edwards way
irvine CA 92614
Manufacturer (Section G)
EDWARDS LIFESCIENCES
1 edwards way
irvine CA 92614
Manufacturer Contact
renee van dorne
1 edwards way
irvine, CA 92614
9492506385
MDR Report Key15439608
MDR Text Key300066139
Report Number2015691-2022-07934
Device Sequence Number1
Product Code NPU
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P130009
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date 11/12/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number9300TFX
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 08/26/2022
Initial Date FDA Received09/16/2022
Supplement Dates Manufacturer Received09/22/2022
11/08/2022
Supplement Dates FDA Received10/18/2022
11/11/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age69 YR
Patient SexFemale
Patient Weight81 KG
-
-