MAUDE Adverse Event Report: ARGON MEDICAL DEVICES T-LOK BONE MARROW BIOPSY NEEDLE 8GA X 4IN

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARGON MEDICAL DEVICES T-LOK BONE MARROW BIOPSY NEEDLE 8GA X 4IN Back to Search Results
Model Number DBMNJ0804TL
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/30/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The sample is indicated as returned.As of the date of this report, the sample has not been evaluated.A follow-up report will be provided once the device has been reviewed.
 
Event or Problem Description
"practitioner was performing bone marrow biopsy as per normal.When she pulled out the biopsy needle and removed the cannula and attempted to push out core biopsy, there was a long piece of metal that came out.No biopsy specimen present.Appears that it came from inside the needle itself.She performed the procedure with another needle successfully.".
 
Additional Manufacturer Narrative
A lot number was not provided, so a batch record review could not be conducted.One opened device was returned for evaluation.Visual inspection found that the trap loc cannula was kinked in two places.All other components were not damaged and found to be manufactured to argon specification.The kinks were straightened out and the obturator was inserted to check for additional metal debris.None was found.The metal piece was not returned for evaluation.Without product to evaluate, determining root cause or corrective action is not possible.If the sample is returned at a future date, this complaint may be reopened for further evaluation at that time.
 
Event or Problem Description
"practitioner was performing bone marrow biopsy as per normal.When she pulled out the biopsy needle and removed the cannula and attempted to push out core biopsy, there was a long piece of metal that came out.No biopsy specimen present.Appears that it came from inside the needle itself.She performed the procedure with another needle successfully.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
T-LOK BONE MARROW BIOPSY NEEDLE 8GA X 4IN
Common Device Name
T-LOK BONE MARROW BIOPSY NEEDLE
Manufacturer (Section D)
ARGON MEDICAL DEVICES
1445 flat creek rd
athens TX 75751
Manufacturer Contact
elnaz rahman
1445 flat creek rd
athens, TX 75751
9036759321
MDR Report Key15445833
Report Number0001625425-2022-01089
Device Sequence Number17343400
Product Code KNW
UDI-Device Identifier00886333001514
UDI-Public00886333001514
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K980196
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,User Facility
Initial Reporter Occupation Physician Assistant
Type of Report Initial,Followup
Report Date (Section B) 10/03/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberDBMNJ0804TL
Device Catalogue NumberDBMNJ0804TL
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/09/2022
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/01/2022
Supplement Date Received by Manufacturer09/01/2022
Initial Report FDA Received Date09/19/2022
Supplement Report FDA Received Date10/03/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention;
Patient SexUnknown
-
-