EXACTECH, INC. LOGIC CR TIB INSERT SLOPE ++, SZ 3.5, 9 MM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED,
|
Back to Search Results |
|
| Model Number |
LOGIC CR TIB INSERT SLOPE ++, SZ 3.5, 9 MM |
| Medical Device Problem Code |
Naturally Worn (2988)
|
| Health Effect - Clinical Code |
Synovitis (2094)
|
| Date of Event |
08/15/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that a 76 yo male patient who was initially implanted on the left knee on (b)(6) 2018, underwent a revision procedure on (b)(6) 2022, approximately 3 years 9 months post the initial revision procedure due to polyethylene wear synovitis.Patient revised with exactech insert and patella.The patient was last known to be in stable condition following the event.No other patient information/medical history reported.
|
| |
|
Additional Manufacturer Narrative
|
|
Recall: z-0021-2022.Concomitant medical products: logic cr femoral por, right, sz 3.5 - 02-010-04-0335, 5079696; three peg patella 38mm - 200-02-38, 5310445; lgc tibial fit tray cem sz 3.5f / 3.5t - 02-012-45-3535, 5160841.Additional information, including the product investigation, will be submitted within 30 days of receipt.
|
| |
|
Additional Manufacturer Narrative
|
|
After review of additional information received the following sections, have been updated accordingly: h6: the revision reported was likely the result of prosthesis wear due to mechanical overload on the posterior medial edge of the tibial insert secondary to the overall tibial slope and potential ligamentous/soft tissue changes resulting in an rotational malalignment between the tibial and femoral components.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay corrected information.The following sections were corrected: b1, b2, b3, b5, d1, g1, h6: component code, type of investigation, investigation findings and investigation conclusions.The revision reported was likely the result of prosthesis wear due to mechanical overload on the posterior medial edge of the tibial insert secondary to the overall tibial slope and potential ligamentous/soft tissue changes resulting in an rotational malalignment between the tibial and femoral components.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
It was reported that a male patient who was initially implanted on the left knee and then underwent a revision procedure, approximately 3 years 9 months post the initial revision procedure due to polyethylene wear synovitis.Patient revised with exactech insert and patella.The patient was last known to be in stable condition following the event.No other patient information/medical history reported.
|
| |
|