| Model Number |
PPM3030 |
| Medical Device Problem Codes |
Migration or Expulsion of Device (1395); Material Integrity Problem (2978); Adverse Event Without Identified Device or Use Problem (2993); Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Codes |
Adhesion(s) (1695); Dysphagia/ Odynophagia (1815); Foreign Body Reaction (1868); Hypoxia (1918); Unspecified Infection (1930); Inflammation (1932); Muscle Weakness/Atrophy (1967); Nausea (1970); Pain (1994); Scar Tissue (2060); Tachycardia (2095); Electrolyte Imbalance (2196); Hernia (2240); Hypernatremia (2242); Respiratory Failure (2484); Confusion/ Disorientation (2553); Abdominal Distention (2601); Thrombosis/Thrombus (4440); Nodule (4551); Unspecified Tissue Injury (4559); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
The patient's attorney alleged a deficiency against the device.The product was used for therapeutic treatment of a ventral hernia.It was reported that after implant, the patient experienced mesh contraction, mesh migration, lack of adequate ingrowth, pain, infection, recurrence, inflammation, adhesions, distention, scarring, mesh encapsulation, and impairment.Post-operative patient treatment included medication.
|
| |
|
Additional Manufacturer Narrative
|
|
If information is provided in the future, a supplemental report will be issued.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional info: ime e2402: abnormal total protein (5.8), abnormal albumin (3.0), hypercapnia, aphasia, diplopia, mass.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Event or Problem Description
|
|
The patient's attorney alleged a deficiency against the device.The product was used for therapeutic treatment of a ventral hernia.It was reported that after implant, the patient experienced mesh contraction, mesh migration, lack of adequate ingrowth, pain, infection, recurrence, inflammation, adhesions, distention, scarring, mesh encapsulation, impairment, labs abnormal for sodium 147, chloride 115, glucose 380, bun 38, total protein 5.8, albumin 3.0, acute respiratory failure with hypoxia and hypercapnia, confusion, not swallowing properly, acute deep vein thrombus, delirium, tachycardia, expressive aphasia, muscle weakness of right upper extremity, diplopia, debility, nausea, & mass.Post-operative patient treatment included medication, hospitalization, intubation, iv fluids, pain medication, iv antibiotics, supplemental oxygen, anticoagulation, occupational therapy, physical therapy, & placement of picc line.
|
| |
|