Model Number 420680
Medical Device Problem Code Patient-Device Incompatibility (2682)
Health Effect - Clinical Code Tissue Breakdown (2681)
Date of Event 08/26/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device 3 of 3.(b)(6).(b)(4).Based on the available information, this event is deemed to be a reportable malfunction.To date no additional information has been received.Should additional information become available, a follow-up report will be submitted.(b)(4).
 
Event or Problem Description
The nurse reported to the company's employee that she had to cease known company¿s dressing and company¿s another dressing evaluation on a diabetic patient who had foot plantar ulcer.The dressing was replaced, and the patient was scheduled for review on (b)(6) 2022.Furthermore, it was mentioned that the exudate was copious over three subsequent changes of dressing and that it did not manage this at all.It was stated that the exudate increased when they started using the first dressing and it appeared that the second dressing applied did not handle the increased exudate at all.The tissue integrity had deteriorated, and the peri wound was macerated.Medical attention was required, and new dressings had to be applied as per that.Peri wound maceration and exudate increased with each new dressing.The dressing was the only variance during this time.She felt that the patient had been compliant with her treatment.The duration of use was unknown.No photograph is available at this time.
 
Additional Manufacturer Narrative
A batch record review was completed, and no discrepancies were found.Aquacel foam adh 10x10cm(1x10) nai was manufactured under system application product (sap) code 1705399 and lot number 1k02072 manufactured on 22 nov 2021.Lot # 1k02072 was sterilized under order (b)(4) and released on review of results of sterilization provided by sterilization company sterigenics.All results were within specification and products were released.No nonconformity was registered during the manufacturing process of lot 1k02072.This was the only complaint for the affected lot registered within database for aquacel not effective.No photographs were received for this complaint.Original samples were requested, but it was confirmed no samples were available, so could not be evaluated in accordance with work instruction (wi).It was therefore not possible to confirm the complaint.Retained samples were available for batch 1k02072, which were tested against the product specification for this product for fluid handling capacity.The laboratory results confirmed that fluid handling capacity for the dressings was within specification.As no nonconformity was identified, no nonconformance record was raised.It is confirmed that the dressings have met specification, so it is expected that the dressings will have been handling exudate as per the expectations and specification of the product.It is possible that exudate levels described in the complaint may have been higher than expected, but it is the responsibility of the healthcare professional to ensure wounds are dressed and monitored appropriately based upon the exudate levels experienced.To date no additional information has been received.Should additional information become available, a follow-up report will be submitted.Fda registration number: reporting site: 1049092.Manufacturing site: 1000317571.
 
Event or Problem Description
To date no additional patient or event details have been received.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AQUACEL FOAM
Common Device Name
DRESSING,WOUND,HYDROPHILIC
Manufacturer (Section D)
CONVATEC LTD
first avenue
deeside industrial park
deeside, flintshire CH5 2 NU
UK  CH5 2NU
Manufacturer (Section G)
CONVATEC LTD
first avenue
deeside industrial park
deeside, flintshire CH5 2 NU
UK   CH5 2NU
Manufacturer Contact
pamela meadows
7815 national service road
suite 600
greensboro, NC 
3365424679
MDR Report Key15482743
Report Number1000317571-2022-00324
Device Sequence Number1817839
Product Code NAC
UDI-Device Identifier00768455127115
UDI-Public00768455127115
Combination Product (Y/N)N
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 08/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/01/2024
Device Model Number420680
Device Catalogue Number420680
Device Lot Number1K02072
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 08/29/2022
Supplement Date Received by Manufacturer11/10/2022
Initial Report FDA Received Date09/26/2022
Supplement Report FDA Received Date12/05/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured11/22/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-