• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. LOCKING TOOL, GALILEO® LAG SCREW; ORTHOPEDIC MANUAL SURGICAL INSTRUMENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. LOCKING TOOL, GALILEO® LAG SCREW; ORTHOPEDIC MANUAL SURGICAL INSTRUMENT Back to Search Results
Model Number LOCKING TOOL, GALILEO® LAG SCREW
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/21/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The contribution of the device to the reported event could not be determined as the device was not returned for evaluation.The root cause of the event could not be determined from the information available and without device evaluation.If the device becomes available for evaluation, a follow-up report will be submitted.
 
Event or Problem Description
On 9/6/2022, it was reported by a sales representative via sems that an 0456-100 locking tool, galileo® lag screw had an issue.During a trocherantic femur/troch nail procedure on (b)(6) 2022, the galileo lag screw inserter broke while inserting a lag screw on a trochanteric femur fracture.The inserter broke where the lag screw attached to the black handle.A piece broke off inside the patient, the broken piece was retrieved from the patient and the case was completed successfully.This was discovered during use with no impact to the patient.
 
Additional Manufacturer Narrative
The complaint is confirmed.(1) unpackaged 0456-100 was received for evaluation.Visual inspection noted the distal tip geometry used for locking had broken.The pattern of the fracture indicates stress caused by excessive torque.Without additional information, the root cause remains undetermined.A probable cause could be attributed to excessive application of mechanical forces via over-torquing the device when attempting to lock it.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LOCKING TOOL, GALILEO® LAG SCREW
Common Device Name
ORTHOPEDIC MANUAL SURGICAL INSTRUMENT
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
vik bajnath
8009337001
MDR Report Key15484297
Report Number1220246-2022-05544
Device Sequence Number17446298
Product Code LXH
UDI-Device Identifier00848665021448
UDI-Public00848665021448
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 11/30/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberLOCKING TOOL, GALILEO® LAG SCREW
Device Catalogue Number0456-100
Device Lot Number14129
Was Device Available for Evaluation? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/06/2022
Supplement Date Received by Manufacturer09/06/2022
Initial Report FDA Received Date09/26/2022
Supplement Report FDA Received Date11/30/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-