Product complaint # (b)(4).This is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Trade name - (b)(4)® active ingredient(s) ¿ triclosan dosage form ¿ suture/solid/parenteral strength ¿ = 2360 ¿g/m (b)(4).Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Are photos available of the patient¿s reaction? please provide the patient's demographic information including age, gender, weight, bmi at the time of index procedure date and name of index surgical procedure? the diagnosis and indication for the index surgical procedure? other relevant patient history/concomitant medications? what was the initial approach for the index surgical procedure? (open, laparoscopic or other)? please describe how was the adhesive was applied? what prep was used prior to, during or after adhesive use? was a dressing placed over the incision? if so, what type of cover dressing used? on what tissue was the suture used? what was the tissue condition (normal, thin, calcified, fragile, diseased)? did the operating surgeon observe any suture deficiency or anomaly before, during, after the suture placement or during any re-operation? was the fixation loop secured to tissue at the initiation of suture use during the index procedure? was at least one reverse stitch performed prior to closure? other relevant patient history/concomitant medications? what is the physician¿s opinion as to the etiology of or contributing factors to this event? please describe the patient manifestations of the reported infection (location, severity, appearance, systemic or local infection).Please provide the onset date/time of infection from the initial surgical procedure.Were there any pre-existing signs/symptoms of active infection prior to this surgical procedure? did the patient receive any prophylactic antibiotics pre-, intra- or post-operation? were cultures performed? if so, please provide the results.How much and what type of drainage is present in this wound? what tissue dehisced? onset date/time of dehiscence? (# post op days) how was the dehiscence managed? how was the infection managed? was any prescription strength medication prescribed? please specify? please describe any surgical intervention performed to address the infection/wound dehiscence.Include dates and results.Please describe the appearance of the suture during the second procedure.Is it known how the wound dehisced? did the sutures untie, break, or pull out of the tissue? were there any precipitating stress factors that led to the suture untying, breaking or pulling out of the tissue? did the operating surgeon observe any suture deficiency or anomaly before, during, after the suture placement and during any re-operation? has the patient used or been exposed to similar glues/agents for repair, crafts, cosmetic use (lashes, nails)? was prineo/dermabond or skin adhesive used on the patient in a previous surgery or wound closure? what is the patient's current status? lot number for the prineo? lot number for the stratafix suture? if applicable, will product be returned? if so, please provide the return date and tracking information.Related medwatch reports - 2210968-2022-08087.
|