MAUDE Adverse Event Report: ARROW INTERNATIONAL LLC ULTRAFLEX IAB: 7.5FR 30CC; SYSTEM, BALLOON, INTRA-AORTIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL LLC ULTRAFLEX IAB: 7.5FR 30CC; SYSTEM, BALLOON, INTRA-AORTIC Back to Search Results
Model Number IPN915321
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/07/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Qn# (b)(4).The device has not been returned for investigation.Teleflex will continue to monitor and trend related events.
 
Event or Problem Description
It was reported that after the catheter was implanted during the operation, the balloon catheter was found ruptured.As a result, a new iab was inserted at the same insertion site.There was no report of patient complications, serious injury or death.There are no available photographs.
 
Additional Manufacturer Narrative
(b)(4), the sample returned for this investigation was deemed as representative sample, as was returned completely sealed/unused.Additional information was received stating the device in question is not available for the investigation.No serial number was reported.The serial number on the returned sample is (b)(6).The lot number 18f22f0020 recorded on the complaint report matches the lot number for the returned sample and on the returned packaging box.Returned for investigation was a 30cc 7.5fr ultraflex intra-aortic balloon catheter (iabc) with the original packaging box that matches the serial number on the returned sample.The sample was returned in a cardboard box and was in the original packaging box/yellow bio-hazard bag.Returned with the sample were semi-finished insertion kit components including 0.025" guidewire, 8fr teflon sheath w/dilator assembly and 8fr teflon sheath w/ sidearm and dilator assemb ly; no damage or abnormalities were noted to the returned components.The returned 8fr teflon sheath w/dilator assembly and 8fr teflon sheath w/ sidearm and dilator assembly appeared unused.Upon return, the semi-finished kit was noted completely sealed and unused.The peel away sheath was noted on the returned iabc.The one-way valve was tethered to the short driveline tubing.The stylet was noted fully inserted within the iabc central lumen.The bladder was noted fully inserted within the original packaging tray.No blood was noted on the exterior surfaces of the returned sample.No visual damage or abnormalities were noted to the returned sample.The bladder thickness was measured at six points and was within specification.The one-way valve was tested and passed.A vacuum was pulled on the one-way valve, and it held for at least 1 minute and then 30 seconds five separate times in accordance with quality system document q-96.The one-way valve was connected to the iabc short driveline tubing, and a negative vacuum was pulled on the iabc.While maintaining the negative vacuum, the iabc was removed from the original packaging tray without any difficulty.Upon removal of the iabc, no damage or abnormalities were noted to the iabc; the iabc bladder was fully wrapped.The stylet was removed from the iabc central lumen without any difficulty.The iabc central lumen was successfully aspirated and flushed using a 60cc lab-inventory syringe.No blood or debris was noted.The iabc was leak tested using the mdt-50 in accordance with testing methods from manufacturing procedure 21-7214 rev.15.No leaks were detected.Full inflation was achieved.The device passed the leak test.The iabc was connected to an iabp with the returned 30cc inflation driveline tubing.The iabc was inserted into the "t" tube and 100mmhg backpressure was applied.The iabc was pumped for a minimum of 30 minutes.There were no alarms triggered.The bladder inflated and deflated completely with each beat.The balloon pressure waveform (bpw) was normal.A lab inventory 0.025in guidewire was back loaded through the iabc distal tip.No resistance was noted; the guidewire was able to advance through the central lumen.No blood or debris was noted.The guidewire was front loaded through the iabc luer.No resistance was noted; the guidewire was able to advance through the central lumen.No blood or debris was noted.A device history record review was conducted for the lot number with no relevant findings.The device passed all manufacturing specifications prior to release.The risk is acceptable.The returned device passed visual and functional testing.The reported complaint that the "balloon catheter was found ruptured" is not confirmed.A representative sample was received for the investigation.The returned sample was completely sealed/unused.The device in question was not returned for the investigation.The returned intra-aortic balloon catheter (iabc) was functionally tested with no leaks or alarms noted.The root cause of the complaint is undetermined.No further action required at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRAFLEX IAB: 7.5FR 30CC
Common Device Name
SYSTEM, BALLOON, INTRA-AORTIC
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL INC.
16 elizabeth drive
chelmsford MA 01824
Manufacturer Contact
effie jefferson
3015 carrington mill blvd
morrisville 27560
9194332672
MDR Report Key15523090
Report Number3010532612-2022-00386
Device Sequence Number14950045
Product Code DSP
UDI-Device Identifier10801902161939
UDI-Public10801902161939
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K000729
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/08/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/31/2024
Device Model NumberIPN915321
Device Catalogue NumberIAB-06830-U
Device Lot Number18F22F0020
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/08/2022
Supplement Date Received by Manufacturer10/28/2022
Initial Report FDA Received Date10/01/2022
Supplement Report FDA Received Date10/31/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/09/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device A
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NONE REPORTED
Patient SexUnknown
-
-