W. L. GORE & ASSOCIATES, INC. GORE® EXCLUDER® AAA ENDOPROSTHESIS; SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT Back to Search Results
Model Number RLT261414
Medical Device Problem Code Insufficient Device Problem Information (3190)
Health Effect - Clinical Code Ruptured Aneurysm (4436)
Date of Event 09/15/2022
Type of Reportable Event Serious Injury
Event or Problem Description
The following was reported to gore: during a scheduled evar for treatment of an abdominal aortic aneurysm on (b)(6) 2022, the patient was implanted with gore® excluder® aaa endoprostheses.The devices were successfully implanted.During the final imaging a type ia or type ii endoleak was identified.As reported, the physician decided to balloon the graft using a non-gore balloon (coda®).During the ballooning a portion of the balloon extended proximal to the graft.A rupture occurred at the time of the ballooning and the patient was converted to open procedure.The patient was reported to be stable and doing fine.
 
Additional Manufacturer Narrative
Conditions/comorbidities: scoliosis, cad, htn, hld.Medications: aspirin 81mg, atenolol 25mg, ferrous fumarate 325mg, hydrochlorothiazide 25mg, lisinopril 10mg, pantoprazole 40mg, plavix 75mg, simvastatin 80mg.Device not accessible for testing: the medical device remains implanted and was therefore not available for return and evaluation.No device problem found: a review of manufacturing records verified that the lot involved in this event met all pre-release specifications.Known inherent risk of device: according to the gore® excluder® aaa endoprosthesis instructions for use (ifu), adverse events that may occur and/or require additional intraoperative procedure time or intervention include, but are not limited to aneurysm rupture.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Additional Manufacturer Narrative
Added component (annex g) code.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® EXCLUDER® AAA ENDOPROSTHESIS
Common Device Name
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
MEDICAL PHOENIX 2 B/P
32470 n. north valley parkway
phoenix AZ 85085
Manufacturer Contact
breanna cox
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key15531603
Report Number3007284313-2022-02140
Device Sequence Number20155092
Product Code MIH
UDI-Device Identifier00733132622450
UDI-Public00733132622450
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
P020004
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/17/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date03/29/2025
Device Model NumberRLT261414
Device Catalogue NumberRLT261414
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/15/2022
Supplement Date Received by Manufacturer09/15/2022
Initial Report FDA Received Date10/03/2022
Supplement Report FDA Received Date10/18/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured03/31/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Life Threatening; Other; Hospitalization; Required Intervention;
Patient Age71 YR
Patient SexMale
Patient Weight69 KG
-
-