• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SIEMENS HEALTHCARE DIAGNOSTICS, INC. ADVIA CENTAUR XP PROGESTERONE (PRGE); PROGESTERONE IMMUNOASSAY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SIEMENS HEALTHCARE DIAGNOSTICS, INC. ADVIA CENTAUR XP PROGESTERONE (PRGE); PROGESTERONE IMMUNOASSAY Back to Search Results
Model Number N/A
Medical Device Problem Code High Test Results (2457)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/26/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A united states customer contacted the siemens customer care center to report a discordant, elevated advia centaur xp progesterone (prge) patient result.The sample collection tube type was bd vacutainer with gel and clot activator and tube size was 13mm x 100mm.The customer confirmed there have been no known shipping/receiving or facility storage issues, and all reagents were handled in accordance with the assay instructions for use (ifu).The reagents were calibrated without issue and all levels of quality control (qc) resulted in range.The customer confirmed all instrument maintenance is current and there have been no signs of system contamination noted, but noted observations of random sample probe integrity errors.Siemens performed a total service call.Sample air pump, sample probe, and sample air tubing was replaced.The system was fully functional on departure.Qc and patients were tested after service and no instrument issues were observed.The limitation section of the ifu states: "heterophilic antibodies in human serum can react with reagent immunoglobulins, interfering with in vitro immunoassays.Patients routinely exposed to animals or to animal serum products can be prone to this interference and anomalous values may be observed.Additional information may be required for diagnosis.The supplement dehydroepiandrosterone (dhea) may cause falsely elevated progesterone results in immunoassays.At an initial concentration of progesterone of 0.70 ng/ml (2.23 nmol/l), a 211% change in concentration was observed at the supraphysiologic level of dheas (dhea metabolite) of 20,000 ng/ml.For patients being treated with dhea, an alternate method that is not expected to show cross-reactivity to dheas (dhea metabolite), such as liquid chromatography-mass spectrometry (lc-ms), should be used.With the advent of new steroid-based medications (analogues) with similar chemical structure to progesterone, there is a possibility of cross-reactivity and falsely elevated results.For diagnostic purposes, the results should always be assessed in conjunction with the patient's medical history, clinical examination and other findings.If the progesterone results are inconsistent with clinical evidence, additional testing is suggested to confirm the result." siemens is investigating.
 
Event or Problem Description
The customer obtained a discordant advia centaur xp progesterone (prge) result on a patient sample that did not match the clinical profile.The physician questioned the result and the sample was retested in a reference laboratory with an alternate method.The result was lower and was more in line with patient clinical profile.A corrected report was issued.There is no report that treatment was altered or prescribed or adverse health consequences due to the discordant, elevated prge result.
 
Additional Manufacturer Narrative
Siemens filed mdr 1219913-2022-00341 initial report on 2022-10-05.Additional information - 2022-11-10 siemens concluded the investigation for a united states customer observation of discordant, elevated advia centaur xp progesterone (prge) results and alleged that the results did not match the patient clinical profile.Sample retesting was performed with an alternate method at a reference laboratory.The alternate testing results recovered lower relative to the initial advia centaur prge results.The customer declined request to provide samples for an internal investigation and was not able to provide the patient clinical information.The customer has had no concerns with quality control (bio-rad immunoassay plus qc lot 40400) results.The limitations section of the advia centaur xp prge instructions for use contains the following statements: "the supplement dehydroepiandrosterone (dhea) may cause falsely elevated progesterone results in immunoassays." "for patients being treated with dhea, an alternate method that is not expected to show cross-reactivity to dheas (dhea metabolite), such as liquid chromatography-mass spectrometry (lc-ms), should be used.With the advent of new steroid-based medications (analogues) with similar chemical structure to progesterone, there is a possibility of cross-reactivity and falsely elevated results." "for diagnostic purposes, the results should always be assessed in conjunction with the patient's medical history, clinical examination and other findings.If the progesterone results are inconsistent with clinical evidence, additional testing is suggested to confirm the result." results between two different platforms (centaur vs.Roche) may not be interchangeable, as evidenced by different reference ranges and control ranges between platforms.A review of siemens' internal medical decision pool (mdp) data for the impacted lot of advia centaur xp prge showed acceptable low-end performance.A review of the siemens complaint database did not identify any similar escalations with this lot of advia centaur xp prge.Based on the available information, a potential product performance issue has not been identified.The customer is operational and no further action is required.In section h6, investigation finding and investigation conclusion codes were updated based on the investigation results.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVIA CENTAUR XP PROGESTERONE (PRGE)
Common Device Name
PROGESTERONE IMMUNOASSAY
Manufacturer (Section D)
SIEMENS HEALTHCARE DIAGNOSTICS, INC.
511 benedict avenue
tarrytown NY 10591 5097
Manufacturer (Section G)
SIEMENS HEALTHCARE DIAGNOSTICS, INC.
333 coney street
east walpole MA 02032
Manufacturer Contact
stacy loukos
333 coney street
east walpole, MA 02032
3392064073
MDR Report Key15547225
Report Number1219913-2022-00341
Device Sequence Number19287059
Product Code JLS
UDI-Device Identifier00630414454641
UDI-Public00630414454641
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
PMA/510(K) Number
A836015
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 12/05/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/18/2022
Device Model NumberN/A
Device Catalogue Number10315522
Device Lot Number307
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/09/2022
Supplement Date Received by Manufacturer11/10/2022
Initial Report FDA Received Date10/05/2022
Supplement Report FDA Received Date12/05/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured08/18/2021
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexFemale
-
-