BOSTON SCIENTIFIC CORPORATION NC EMERGE; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS Back to Search Results
Model Number 7212
Medical Device Problem Codes Material Puncture/Hole (1504); Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/01/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Date of event: used the first day of the month of the bsc aware date since event date was not provided.
 
Event or Problem Description
It was reported that shaft hole occurred.A 3.25mm x 12mm nc emerge balloon catheter was selected for dilation.However, the wire would not feed through the balloon shaft when the balloon was tried to load on the wire and a shaft hole was noted.The device was replaced with a new nc emerge balloon catheter and the procedure was completed successfully.There were no patient complications nor injuries reported.
 
Additional Manufacturer Narrative
B3 date of event: used the first day of the month of the bsc aware date since event date was not provided.Returned product consisted of an nc emerge balloon catheter.The device was visually and microscopically examined.There was contrast present in the inflation lumen.The guidewire lumen was buckled and prolapsed 2mm distal from the bicomponent weld, at 1mm in length.Within this buckle were two punctures in the lumen indicative to an interaction with a guidewire.At 5mm distal from the bicomponent weld, for a length of 1mm, the guidewire lumen was buckled and prolapsed, without signs of puncture, for a second segment.The balloon had tight folds.Further inspection of the remainder of the device presented no other damage or irregularities.
 
Event or Problem Description
It was reported that shaft hole occurred.A 3.25mm x 12mm nc emerge balloon catheter was selected for dilation.However, the wire would not feed through the balloon shaft when the balloon was tried to load on the wire and a shaft hole was noted.The device was replaced with a new nc emerge balloon catheter and the procedure was completed successfully.There were no patient complications nor injuries reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NC EMERGE
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer Contact
jay johnson johnson
4100 hamline ave n
arden hills, MN 55112
6515810888
MDR Report Key15554528
Report Number2124215-2022-39718
Device Sequence Number12387463
Product Code LOX
UDI-Device Identifier08714729846406
UDI-Public08714729846406
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
K141236
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 11/07/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/30/2023
Device Model Number7212
Device Catalogue Number7212
Device Lot Number0028469743
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 09/22/2022
Supplement Date Received by Manufacturer11/01/2022
Initial Report FDA Received Date10/06/2022
Supplement Report FDA Received Date11/07/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured11/30/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1