Device report from synthes reports an event in portugal as follows: it was reported on an unknown date that - 03.010.041 b 14.0/3.2 mm punzón, damaged canulated.03.010.063 hystic protection plane 12.0/8.0, longitud 188 mm, and a 03.010.065 bit guide 8.0/4.2, for part no.03.010.063, very difficult to remove from each other.There was no surgical delay.There was alteration of the technique by another surgical option existing in the surgical instrument, with no impact on the surgery.There was no patient consequences.This report is for a 14.0mm cannulated awl this is report 3 of 3 for complaint (b)(4).
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Additional narrative: unknown event date reporter is a j&j sales representative.Investigation summary the product was returned to depuy synthes for evaluation.The depuy synthes team conducted a visual inspection of the returned device.Visual analysis of the returned sample revealed that the awl ø14/3.2 cann was broken from the tip.The broken fragment was not returned.No other defect was found.A dimensional inspection for the awl ø14/3.2 cann was unable to be performed due to post manufacturing damage.The observed condition of the device was consistent with a random component failure that may have been caused by exposure to unintended forces.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was confirmed as the observed condition of the awl ø14/3.2 cann would contribute to the complained device issue.There is no indication that a design or manufacturing issue has caused the complaint condition and hence the root cause cannot be determined.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Drawing/specifications reviewed: yes conforms dimensional inspection: n/a device history part: : 03.010.041 lot no : 3l03639 release to warehouse date: 11 feb 2019 manufacturing site: (b)(4).A manufacturing record evaluation was performed for the finished article lot and no non-conformances were identified.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|