Model Number M0035423060
Medical Device Problem Code Premature Separation (4045)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/18/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device is not available to the manufacturer.
 
Event or Problem Description
It was reported during the procedure while re-positioning the subject coil and re-inserting it into the catheter, the device was detached from the delivery wire and stuck in the catheter.The physician used a guidewire to remove the detached coil from the catheter.The procedure was completed successfully with no clinical consequences to the patient.
 
Event or Problem Description
It was reported during the procedure while re-positioning the subject coil and re-inserting it into the catheter, the device was detached from the delivery wire and stuck in the catheter.The physician used a guidewire to remove the detached coil from the catheter.The procedure was completed successfully with no clinical consequences to the patient.
 
Additional Manufacturer Narrative
Due to the automated mes system there are controls in the manufacturing process to ensure the product met specifications upon release.During visual inspection the main coil was found to be detached/separated and kinked/bent.A functional inspection for the reported 'coil in catheter friction' could not be performed as the main coil was detached.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.The device was returned and analyzed.The reported main coil prematurely detached/separated during use was confirmed during the analysis.The device failed to meet specifications when received for complaint investigation based on the analyzed anomalies noted to the device.The main coil was found to be detached/separated and kinked/bent.An assignable cause of procedural factors will be assigned to the as reported and as analyzed 'main coil prematurely detached/separated during use', as the issues are associated with a product that meets stryker design and manufacture specifications and was used in according with the dfu but due to procedural and/or anatomical factors during use, the product performance was limited.An assignable cause of handling damage was assigned to the as analyzed 'main coil kinked/bent' as the defect appears to be associated with handling of the product or portion of the product during the procedure.An assignable cause of 'not confirmed' will be assigned to the as reported 'coil in catheter friction ' as the coil was separated/detached from the coil delivery wire when returned and could not be confirmed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TARGET 360 ULTRA 3MM X 6CM
Common Device Name
DEVICE, NEUROVASCULAR EMBOLIZATION
Manufacturer (Section D)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI  NA
Manufacturer (Section G)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI   NA
Manufacturer Contact
tara lopez
47900 bayside parkway
fremont, CA 94538
5104132500
MDR Report Key15580908
Report Number3008881809-2022-00502
Device Sequence Number17698417
Product Code HCG
UDI-Device Identifier04546540675880
UDI-Public04546540675880
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K153658
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 12/12/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/02/2025
Device Model NumberM0035423060
Device Catalogue NumberM0035423060
Device Lot Number23514584
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/21/2022
Supplement Date Received by Manufacturer11/29/2022
Initial Report FDA Received Date10/11/2022
Supplement Report FDA Received Date12/12/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/04/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
GUIDEWIRE (UNKNOWN).; SL-10 MICROCATHETER (STRYKER).
Patient SexUnknown
-
-