| Model Number |
EX061703CS |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/12/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Manufacturing review: additional complaints have not been reported for this lot.Based on the information available it is not reasonably suggested that a manufacturing process may have caused or contributed to the reported issue.However, the lot history records of this lot were reviewed with special attention to the manufacturing and inspection of this product and the product was found to have met the specification prior to shipment.Investigation summary: the sample was not returned for evaluation and no photos of the device were provided.Therefore, the investigation is inconclusive for the reported issue.The definitive root cause could not be determined based upon available information.Labeling review: it is not clear where the catheter broke, and which components were involved.It is also not clear at what stage of the procedure the catheter broke.In reviewing the relevant labeling for this product potential issues were found addressed.In regard to tracking issues the instructions for use state: 'if resistance is met during stent system introduction, the stent system should be removed and another stent system should be used.¿, and 'if resistance is met while retracting the delivery system over a guidewire, remove the delivery system and guidewire together.' in regard to a deployment related issue the instructions for use state: 'if excessive force is felt during stent deployment, do not force the delivery system.Remove the delivery system and replace with a new unit.' the instructions for use further state: 'predilation of the lesion should be performed using standard techniques.', and 'gain femoral access at the appropriate site using a 6f (2.0 mm) or larger introducer sheath.Insert a 0.035¿diameter guidewire of appropriate length'.In regard to damage, the instructions for use state: 'examine the stent system for any damage.If it is suspected that the sterility or performance of the device has been compromised, the stent system should not be used.' expiry date: 07/2022.
|
| |
|
Event or Problem Description
|
|
It was reported that during a stent placement procedure in the right femoral artery, the device allegedly broke.There was no reported patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
H10: manufacturing review: additional complaints have not been reported for this lot, previously.Based on the information available it is not reasonably suggested that a manufacturing process may have caused or contributed to the reported issue.However, the lot history records of this lot were reviewed with special attention to the manufacturing and inspection of this product and the product was found to have met the specification prior to shipment.Investigation summary: the physical sample was returned for evaluation.The returned sample was found with locked shipping lock, the stent was still loaded, and the black stability sheath was found broken which leads to confirmed result for break.A 7f introducer with 0.035" guidewire was used, and the guidewire was running smoothly inside the system; the vessel was not tortuous, and the lesion was pre dilated.Based on information available the investigation is closed with confirmed result for stability sheath break.A definitive root cause could not be determined based upon the available information.Labeling review: in reviewing the relevant labeling for this product potential issue was found addressed.In regards to tracking issues the instructions for use state: 'if resistance is met during stent system introduction, the stent system should be removed and another stent system should be used.' the instructions for use further state: 'predilation of the lesion should be performed using standard techniques.', and 'gain femoral access at the appropriate site using a 6f (2.0 mm) or larger introducer sheath.Insert a 0.035¿ diameter guidewire of appropriate length'.In regards to damage, the instructions for use state: 'examine the stent system for any damage.If it is suspected that the sterility or performance of the device has been compromised, the stent system should not be used.' h10: d4 (expiry date: 07/2022).H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported that during a stent placement procedure in the superficial femoral artery through left femoral approach, the device allegedly broke.There was no reported patient injury.
|
| |
|