MAUDE Adverse Event Report: COLOPLAST A/S RESTORELLE DIRECTFIX ANTERIOR; SURGICAL MESH

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COLOPLAST A/S RESTORELLE DIRECTFIX ANTERIOR; SURGICAL MESH Back to Search Results
Model Number 5014502400
Medical Device Problem Code Migration (4003)
Health Effect - Clinical Codes Erosion (1750); Nausea (1970); Pain (1994); Scar Tissue (2060); Skin Erosion (2075); Urinary Retention (2119); Abnormal Vaginal Discharge (2123); Vomiting (2144); Burning Sensation (2146); Urinary Frequency / Polyuria (2275); Prolapse (2475); Intermenstrual Bleeding (2665); Dysuria (2684); Kidney Infection (4502); Dyspareunia (4505)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Coloplast has not been provided any corroborating evidence to verify the information contained in this report.Without the benefit of examination and testing, coloplast is precluded from commenting on the condition of the device or the cause of the occurrence.Should additional facts prompt us to alter or supplement any information or conclusions contained in the original mdr or in any prior supplemental reports, a follow-up report will be submitted.
 
Event or Problem Description
As reported to coloplast, though not verified, legal representative stated the patient was implanted with a 30x30 cm device and a device from another manufacturer on (b)(6) 2016.The doctor dissected through the patient's vagina at the level of the mid-urethra and implanted the other manufacturers device transvaginally using trocars that were provided in the other manufacture's kit.The doctor used the trocars to force the other manufacture's device from the vaginal incisions into the suprapubic incisions.The tape was then brought out through the skin incisions during cystoscopy.The device was tensioned, the plastic sheath was removed, and the device was cut at the level of the skin.During the implant procedure, the doctor cut the 30x30cm device into a 24x6cm strip and implanted the device through the vagina for correction of the patient's posterior pelvic organ prolapse.The proximal portion of the device was left in the rectovaginal space for retrieval later in the procedure.After suturing the device transvaginally, the da vinci robot via abdominal dissection was used to access the device left in the patient's posterior compartment during the transvaginal portion of the procedure.The doctor located and delivered the posteriorly placed device into the pelvis and anchored the posterior device to the posterior vagina.The fixation extended out the lateral vaginal at the level of the uterosacral ligaments.A similar size piece of the device (24x5cm) was introduced abdominally using the da vinci robot to correct the patient's anterior pelvic organ prolapse.The doctor anchored the device for the anterior repair to the anterior vagina with fixation extending distally to the level of the bladder neck, laterally to the lateral vagina, and apically to the apex of the anterior vagina.The doctor then joined the two large pieces of device by grasping both pieces, fashioning them over the patient's sacrum and anchored both pieces of device together to the sacral promontory.The patient returned to the operating room for a revision surgery on april 3,2017.During the procedure, the doctor performed a bilateral salpingooopherectomy and then addressed the other manufacturer's device.According to the operative note, the doctor identified the prior other manufacturers device had "freed and mobilized [it] away from the vagina and also away from the overlying urethra." the doctor implanted a second other manufacturer's device.The second other manufacturers device was placed with increased tension and was lying slightly proximal to the previously placed device.The patient reported experiencing erosion, pain, device removal procedures, and surgeries.The patient returned to the operation room for a second revision performed by the doctor on october 1, 2018.During this procedure, the doctor implanted a device vaginally to correct anterior prolapse.The patient returned to the operation room for a third revision performed by the doctor on november 2, 2018.Prior to the procedure, the patient was experiencing incomplete bladder emptying.During this procedure, the patient removed one of the prior other manufacturer's devices from sulci to sulci.According to the operative note, the device was fully mobilized laterally, then transected and then freed from the overlying urethra, then excised lateral to the sulci bilaterally.The patient returned to the operating room for a fourth revision performed by the doctor on october 19, 2019.The patient preoperative diagnosis for this surgery was dyspareunia and nonspecific lower pelvic pain following prior vaginal device repair.The diagnoses were confirmed during the procedure.The doctor performed a revision of the anterior vaginal device and subsequent anterior repair with cervicopexy.During this procedure, the doctor identified the device, and removed using a dissection that extended laterally to expose the path of the device towards the sacrospinous ligaments.The doctor took the distal section to the level of the bladder neck in removing device.The doctor used a non-polypropylene biologic graft to reduce the bladder prolapse that was caused from removal of the device.On october 20, 2020, the patient returned to the operating room for a fifth revision, this revision procedure was performed by a different doctor.Prior to this revision surgery, the doctor diagnosed the patient with dyspareunia, sexual pain, and vaginal wound after anterior vaginal device and biologic graft surgeries.The doctor confirmed these diagnoses post-op.During the procedure, the doctor removed additional portions of the device placed anteriorly and sutured the vaginal wound.The doctor found transverse anterior vaginal wall banding with dyspareunia, sexual pain, and vaginal scarification.According to the pathology records, 5 cm x 5 cm in aggregate of device was removed during this procedure.
 
Event or Problem Description
Additional information received on 9/19/2023 indicates the patient was experiencing, urinary frequency, urinary tract infections, bleeding after intercourse, dysuria, a burning sensation, vaginal discharge and mesh exposure was observed.
 
Event or Problem Description
Additional information received on 11/6/2023 provides patient symptoms as follows: nausea and vomiting.
 
Additional Manufacturer Narrative
Corrections: item number, lot number, udi number, catalogue number.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RESTORELLE DIRECTFIX ANTERIOR
Common Device Name
SURGICAL MESH
Manufacturer (Section D)
COLOPLAST A/S
holtedam 1
humlebæk 3050
DA  3050
Manufacturer (Section G)
COLOPLAST MANUFACTURING US, LLC
1601 west river road north
minneapolis MN 55411
Manufacturer Contact
usbes brian e schmidt
1601 west river road north
minneapolis, MN 55411
8007880293
MDR Report Key15587200
Report Number2125050-2022-01061
Device Sequence Number14143804
Product Code FTL
UDI-Device Identifier05708932484022
UDI-Public05708932484022
Combination Product (Y/N)N
PMA/510(K) Number
K103568
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2019
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 11/09/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/29/2020
Device Model Number5014502400
Device Catalogue Number501450
Device Lot Number5925687
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/13/2022
Supplement Date Received by Manufacturer09/19/2023
10/17/2023
11/06/2023
Initial Report FDA Received Date10/12/2022
Supplement Report FDA Received Date09/29/2023
11/02/2023
11/09/2023
Date Device Manufactured11/30/2017
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age41 YR
Patient SexUnknown
-
-