Per rep - (b)(6) 2022 - the customer stated that the patient came back in with indurated skin lesions.They wonder if the paclitaxel might be responsible for this.Patient outcome: 6.3.1.1 did any unintended section of the device remain inside the patient¿s body? no, if yes, please describe.6.3.1.2 was the patient hospitalized or was there prolonged hospitalization due to this occurrence? -no.6.3.1.3 did the patient require any additional procedures due to this occurrence? -no if yes, please describe.6.3.1.4 did the product cause or contribute to the need for additional procedures? -no if yes, please specify additional procedures and provide details.6.3.1.5 has the complainant reported any adverse effects on the patient due to this occurrence? -possibly.6.3.1.6 has the complainant reported that the product caused or contributed to the adverse effects? -possibly.Please specify adverse effects and provide details.-indurated skin lesions.Additional info: 3.60 are images (e.G.Angiography, us etc.) of the device and/or procedure available? n/a, yes, no -no.3.61 was the device flushed before the procedure, as per ifu? n/a, yes, no -yes 3.62 were there any issues with flushing of the device? n/a, yes, no -no.3.63 details of the access sheath used (name, fr size,length)? -g44154, lot 14813607.3.64 details of the wire guide used (name, diameter, hyrdophyllic)? -.035, not cook, not hydrophilic.3.65 what approach was used to access the target site? contralateral, ipsilateral, antegrade, retrograde, other -contralateral.Please specify for other: if contralateral, was the bifurcation angle steep? n/a, yes, no -no.3.66 what was the target location for the stent? -left sfa.3.67 what artery was the stent placed in? proximal sfa, mid sfa, distal sfa, at the ostium of the profunda, p1 (proximal popliteal), other -entire sfa.Please specify for other: 3.68 was the wire guide removed from the patient prior to advancing the delivery system? n/a, yes, no -no.3.69 if removed, was the wire guide wiped prior to advancement of the delivery system? n/a, yes, no -n/a.3.70 did the stent delivery system cross the target location? n/a, yes, no -yes 3.71 was pre-dilation performed ahead of placement of the stent? n/a, yes, no -yes 3.72 was the patient¿s anatomy difficult or altered? previous bypass, tortuous, calcified, altered, other -no.If other, please specify: 3.73 was resistance encountered when advancing the wire guide? n/a, yes, no -no.3.74 was resistance encountered when advancing the delivery system to the target location? n/a, yes, no -no.3.75 was resistance encountered when deploying the stent? n/a, yes, no -no.3.76 how did the physician deal with any resistance encountered? -no resistance.3.77 was the stent fully deployed in the patient before removing the delivery system? n/a, yes, no -yes.3.78 after deployment did the stent show signs of any of the following: compression, fracture, deformation, constraint, elongation, other -no.If other, please specify: 3.79 was post-dilation performed after the placement of the stent? n/a, yes, no -yes.3.80 did any portion of the device break off? n/a, yes, no -no.If yes, please state what part: 3.81 when did the device break? n/a, prep, advancement, deployment, withdrawal, after removal -n/a.3.82 thumbwheel only ¿ was the distal end of the stability sheath inside the access sheath? n/a, yes, no -unkr.3.83 thumbwheel only ¿ was the retraction sheet being held during deployment.N/a, yes, no -no.3.84 did the thumbwheel spin freely or rotate without stent release or without retracting the stent retraction sheath? n/a, yes, no -it rotated freely and the stents deployed.If yes, was the stent partially deployed? n/a, yes, no -n/a.If yes, was the partially deployed stent removed with the delivery system or was it deployed in the patient? n/a, removed, deployed.3.85 if removed, did any part of the stent fracture during removal of the delivery system? n/a, yes, no -n/a.3.86 was the delivery system kinked or twisted during advancement or deployment? n/a, yes, no -no.3.87 please advise if and when any damage was observed on the; -n/a.3.87.1 wireguide n/a, yes, no -n/a.Prior to use, during use, post procedure.3.87.2 delivery system n/a, yes, no -no.Prior to use, during use, post procedure.If yes, please specify (e.G.Kinked or twisted): 3.88 what intervention (if any) was required? -none.3.89 was the secondary intervention performed during the same procedure as the device failure or was it scheduled for another day? n/a, same procedure, another day -none.3.90 were any other defects (other than the complaint issue) observed on the delivery system prior to return (e.G.Kink)? n/a, yes, no -no.Please specify if yes.
|