MAUDE Adverse Event Report: ARROW INTERNATIONAL LLC ULTRAFLEX IAB: 7.5FR 40CC; SYSTEM, BALLOON, INTRA-AORTIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL LLC ULTRAFLEX IAB: 7.5FR 40CC; SYSTEM, BALLOON, INTRA-AORTIC Back to Search Results
Model Number IPN039788
Medical Device Problem Code Material Twisted/Bent (2981)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/21/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
It was reported that "the balloon could not move forward normally after insertion, after checking it, it was found that the catheter was severely kinked and could not be used normally, so a new catheter was replaced for smooth insert." additional information states that the secondary catheter was inserted at the same insertion site.No report of patient harm or injury.
 
Additional Manufacturer Narrative
Qn# (b)(4).No serial number was reported.The serial number on the returned sample is (b)(6).The lot number (18f22c0022) recorded on the complaint report matches the lot number for the returned sample.Returned for investigation was a 40cc 7.5fr ultraflex intra-aortic balloon catheter (iabc) without the original packaging.The sample was returned in a cardboard box and was in a clear plastic bag.Upon return, the peel away sheath was noted on the returned iabc.The one-way valve was tethered to the short driveline tubing.The iabc bladder was fully unwrapped.A kink to the iabc central lumen was noted at approximately 22.4cm from the iabc distal tip.Dried blood was noted on the exterior surfaces of the returned iabc; no blood was noted within the helium pathway.No other damage or abnormalities were noted to the returned sample.The one-way valve was tested and passed.A vacuum was pulled on the one-way valve, and it held for at least 1 minute and then 30 seconds five separate times.The iabc central lumen was aspirated and flushed using a syringe.No abnormalities or debris were noted.The iabc was leak tested.No leaks were detected.Full inflation was achieved.The device passed the leak test.A guidewire was back loaded through the iabc distal tip.The guidewire could not advance at approximately 22.4cm from the iabc distal tip, which is the location of the previously noted kink.No blood or debris was noted.The guidewire was front loaded through the iabc luer.The guidewire could not advance at approximately 59.6cm from the iabc luer, which is the location of the previously noted kink.No blood or debris was noted.A device history record (dhr) review was conducted for the lot number with no relevant findings.The device passed all manufacturing specifications prior to release.The reported compliant of iab kinked is confirmed.A kink to the central lumen was noted during the visual inspection of the returned iab catheter, and a guidewire could not pass successfully through the iabc central lumen during functional testing.Based on a review of the device history record (dhr), the product met specification upon release; however, the specifications were not met during the complaint investigation due to the kinked central lumen.The root cause of the kink is undetermined.The most probable potential cause is customer handling.No further action required at this time.This will be monitored for any developing trends.
 
Event or Problem Description
It was reported that "the balloon could not move forward normally after insertion, after checking it, it was found that the catheter was severely kinked and could not be used normally, so a new catheter was replaced for smooth insert." additional information states that the secondary catheter was inserted at the same insertion site.No report of patient harm or injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRAFLEX IAB: 7.5FR 40CC
Common Device Name
SYSTEM, BALLOON, INTRA-AORTIC
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL INC.
16 elizabeth drive
chelmsford MA 01824
Manufacturer Contact
bryanna connelly
3015 carrington mill blvd
morrisville 27560
MDR Report Key15615945
Report Number3010532612-2022-00409
Device Sequence Number20851351
Product Code DSP
UDI-Device Identifier10801902145731
UDI-Public10801902145731
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K000729
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 09/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Expiration Date02/28/2024
Device Model NumberIPN039788
Device Catalogue NumberIAB-06840-U
Device Lot Number18F22C0022
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/22/2022
Supplement Date Received by Manufacturer11/10/2022
Initial Report FDA Received Date10/17/2022
Supplement Report FDA Received Date11/10/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/14/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
N/A.; N/A.
Patient Age69 YR
Patient SexMale
-
-