| Model Number |
542-11-62H |
| Medical Device Problem Codes |
Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Code |
Insufficient Information (4580)
|
| Date of Event |
08/15/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.Should additional information become available it will be reported in a supplemental report upon completion of the investigation.
|
| |
|
Event or Problem Description
|
|
Distributor reported that, "patient required a total revision of right hip.".
|
| |
|
Additional Manufacturer Narrative
|
|
Reported event: an event regarding revision involving a trident shell was reported.The event was not confirmed.Method & results: -product evaluation and results: visual inspection of the returned device indicated nothing remarkable.The device has bone adhered to the outer surface consistent with implantation in the body.-clinician review: no medical records were received for review with a clinical consultant -product history review: review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.-complaint history review: there have been no other similar events for the lot referenced.Conclusions: it was reported that the patient was revised.It is unknown why the shell, metal head, liner and stem were revised.The exact cause of the event could not be determined because insufficient information was provided.Further information such as pathology reports, pre- and post-operative x-rays and the primary operative report as well as patient history and follow-up notes are needed to complete the investigation for determining root cause.No further investigation for this event is possible at this time.If additional information become available to indicate further evaluation is warranted, this record will be reopened.
|
| |
|
Event or Problem Description
|
|
Distributor reported that, "patient required a total revision of right hip." update 11/15/2022: based on product inspection of the returned device, loss of taper lock was noted.
|
| |
|
Additional Manufacturer Narrative
|
|
Reported event: an event regarding revision involving a trident shell was reported.The event was not confirmed.Method & results: -product evaluation and results: visual inspection of the returned device indicated nothing remarkable.The device has bone adhered to the outer surface consistent with implantation in the body.-clinician review: a review of the provided medical records by a clinical consultant indicated: 'this patient underwent a right primary total hip replacement at some point in the past.He developed symptoms related to trunnion deformity with loosening of the femoral head with metallosis and bone loss with elevated metal ion levels.A two-stage revision was carried out initially to debride the hip, inserting a spacer and then at a second operation the hip was reconstructed.I can confirm that the first revision and the second revision occurred since i was able to review the operation reports.I cannot determine the root cause of this event with certainty.The causes of trunnionosis and metallosis elevated metal ion levels are multifactorial including surgical technique factors, patient activity level and bmi, and implant factors.The explanted prosthesis should be returned to stryker for examination and analysis by engineers.-product history review: review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.-complaint history review: there have been no other similar events for the lot referenced.Conclusions: it was reported that the patient was revised due to disassociation of the head from the stem.It is unknown why the shell was removed.The exact cause of the event could not be determined because insufficient information was provided.No further investigation for this event is possible at this time.If additional information become available to indicate further evaluation is warranted, this record will be reopened.
|
| |
|
Event or Problem Description
|
|
Distributor reported that, "patient required a total revision of right hip." update (b)(6)2022: based on product inspection of the returned device, loss of taper lock was noted.30 june 2023 - med review states:on (b)(6) 2022, the patient underwent a revision at which time black fluid and black staining of the hip was noted.The femoral head was loose on the trunnion and the trunnion was eroded.Elevated iron levels were present.The femoral stem was well fixed but there was bone loss present.It was decided to delay reconstruction and a spacer was implanted.'.
|
| |
|