Catalog Number 305274
Medical Device Problem Code Material Puncture/Hole (1504)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/26/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Date of event: unknown.The date received by manufacturer has been used for this field.Fda notified?: the initial reporter also notified the fda via medwatch # mw5111968.A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that the tip of the plunger in the bd intregra¿ syringe with detachable needle pierced through the stopper during the injection, resulting in the patient not getting a full dose of medication.The following information was provided by the initial reporter: "while giving an injection with a bd integra syringe, the metal tip of the plunger broke through the plunger stopper.As a result, the patient received less than a full dose of medication.".
 
Event or Problem Description
It was reported that the tip of the plunger in the bd intregra¿ syringe with detachable needle pierced through the stopper during the injection, resulting in the patient not getting a full dose of medication.The following information was provided by the initial reporter: "while giving an injection with a bd integra syringe, the metal tip of the plunger broke through the plunger stopper.As a result, the patient received less than a full dose of medication.".
 
Additional Manufacturer Narrative
H6: investigation summary one sample was provided to our quality team for investigation.Through visual inspection, it was observed that the cutter of the integra syringe had punctured through the stopper and the needle had not retracted.An unused physical sample is required for a more thorough evaluation.Potential root cause for the premature retraction defect is associated with the assembly process.These conditions are occurring below their expected frequency so no corrective action is required at this time.A device history record review was completed for provided lot number 1029961.A review showed no rejected inspections or quality issues during the production that could have contributed to the reported defect.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD INTREGRA¿ SYRINGE WITH DETACHABLE NEEDLE
Common Device Name
PISTON SYRINGE
Manufacturer (Section D)
BECTON DICKINSON MEDICAL SYSTEMS
route 7 and grace way
canaan CT 06018
Manufacturer (Section G)
BECTON DICKINSON MEDICAL SYSTEMS
route 7 and grace way
canaan CT 06018
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key15643232
Report Number1213809-2022-00738
Device Sequence Number6224624
Product Code MEG
UDI-Device Identifier00382903052745
UDI-Public(01)00382903052745
Combination Product (Y/N)N
Initial Reporter StateMD
Initial Reporter CountryUS
PMA/510(K) Number
K011103
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/27/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date01/31/2026
Device Catalogue Number305274
Device Lot Number1029961
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/11/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/26/2022
Supplement Date Received by Manufacturer10/27/2022
Initial Report FDA Received Date10/20/2022
Supplement Report FDA Received Date11/10/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/29/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-