ASAHI INTECC GAIA THIRD; GUIDE WIRE
Back to Search Results
Model Number
AHW14R311P
Medical Device Problem Code
Material Separation (1562)
Health Effect - Clinical Code
No Clinical Signs, Symptoms or Conditions (4582)
Date of Event
10/06/2022
Type of Reportable Event
Malfunction
Event or Problem Description
Tip of gaia third separated and detached while attempting to cross cto of om.The tip became stuck behind a stent strut and detached.
Search Alerts/Recalls
New Search
|
Submit an Adverse Event Report
Brand Name
GAIA THIRD
Common Device Name
GUIDE WIRE
Manufacturer
(Section D)
ASAHI INTECC
3-100 akatsuki-cho
seto, aichi 489-0 071
JA 489-0071
MDR Report Key
15651805
Report Number
3004718255-2022-00276
Device Sequence Number
14067257
Product Code
DQX
UDI-Device Identifier
04547327094795
UDI-Public
(01)04547327094795(17)240630(10)210722A401
Combination Product (Y/N)
N
Initial Reporter State
FL
Initial Reporter Country
US
Number of Events Summarized
1
Summary Report (Y/N)
N
Serviced by Third Party (Y/N)
Unknown
Reporter Type
Importer
Initial Reporter Occupation
Physician
Type of Report
Initial
Report Date
(Section B)
10/21/2022
Report Date
(Section F)
10/21/2022
1
Device was Involved in the Event
1
Patient was Involved in the Event
Is this an Adverse Event Report?
No
Is this a Product Problem Report?
Yes
Operator of Device
Health Professional
Device Expiration Date
06/30/2024
Device Model Number
AHW14R311P
Device Catalogue Number
AHW14R311P
Device Lot Number
210722A401
Was Device Available for Evaluation?
Yes
Is the Reporter a Health Professional?
Yes
Was the Report Sent to FDA?
Yes
Distributor Facility Aware Date
10/07/2022
Device Age
14 MO
Event Location
Hospital
Date Report to Manufacturer
10/21/2022
Initial Date Received by Manufacturer
Not provided
Initial Report FDA Received Date
10/21/2022
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number
1
Patient Age
75 YR
Patient Sex
Male
Patient Weight
86 KG
Date Report Sent to FDA
10/21/2022
-
-