DEPUY MITEK LLC US BIO-INTRAFIX TAPERED SCREW, 7-9 MM X 30 MM; SOFT-TISSUE ANCHOR, BIOABSORBABLE
|
Back to Search Results |
|
| Model Number |
254628 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
09/16/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by depuy mitek or its employees that the report constitutes an admission that the device, depuy mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Udi: (b)(4).To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported by a healthcare professional in china that during a anterior cruciate ligament reconstruction procedure on (b)(6) 2022, it was observed that the anchor on the bio-intrafix tibial sheath - large device was broken off.Removed all the broken parts.Another like device was used to complete the surgery.There were no adverse consequences to the patient nor surgical delay reported.No additional information could be provided.
|
| |
|
Event or Problem Description
|
|
It was reported by a healthcare professional in china that during a anterior cruciate ligament reconstruction procedure on (b)(6) 2022, it was observed that the bio-intrafix tapered screw, 7-9 mm x 30 mm device was broken off.Removed all the broken parts.Another like device was used to complete the surgery.There were no adverse consequences to the patient nor surgical delay reported.No additional information could be provided.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by depuy mitek or its employees that the report constitutes an admission that the device, depuy mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Investigation summary :the product was returned to mitek for evaluation.Mitek then conducted visual inspection of device received.Only the sleeve was received for evaluation.The sheaths of the sleeve were cracked.Since the anchor was not returned, this complaint cannot be confirmed.A manufacturing record evaluation was performed for the finished device lot number: 8l58086, and no non-conformances were identified.At this time, with the information provided, a definite root case cannot be determined for this failure.The anchor breakages are associated with off -axis insertion, levering during insertion or excess tension applied on sutures which caused damage on the anchor during the use.The possible root cause can be related with the damage in the anchor which could¿ve caused the anchor to fall off the inserter.However, it cannot be conclusively affirmed.As per ifu, failure to use the guidewire may result in the tibial tapered screw diverging through the tibial sheath.) place the appropriate size (refer to sizing guideline instructions above) tibial tapered screw onto the hex driver and slide them over the guide wire into the tibial sheath.Apply tension on the graft strands distally, and insert the tibial tapered screw until it is flush with the tibial cortex.At this time, no corrective action is required, and no further action is warranted, as the device was repaired and is fully functional.However, depuy synthes mitek will continue to track any related complaints within this device family to monitor the extent to which this complaint is observed in the field.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by depuy mitek or its employees that the report constitutes an admission that the device, depuy mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H6: the actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|