BOSTON SCIENTIFIC NEUROMODULATION LINEAR; STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF Back to Search Results
Model Number SC-2158-70
Medical Device Problem Codes Fracture (1260); High impedance (1291)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/03/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the patients lead had high impedances.The patients leads were explanted wherein the left cervical leads distal tip were left behind.The patient was doing well postoperatively.
 
Additional Manufacturer Narrative
Approximated based on the date the manufacturer became aware of the event.Additional suspect medical device component involved in the event: product family: scs-linear leads; upn: m365sc2218500; model: sc-2218-50; serial: (b)(4); batch: 20668686.
 
Additional Manufacturer Narrative
Sc-2158-70 sn: (b)(6).The returned lead was analyzed, and x-ray inspection revealed that one of the cables was fractured within the distal array.With all the available information, boston scientific concludes the reported event was confirmed.The distal tip and electrode were separated from the distal array.The cables are exposed at the damaged portion of the lead.It appears that resistances were felt during the lead pull and was subjected to an excessive tensile load causing damage to the distal array.The probable cause was unintended use error which caused or contributed to the event.Sc-2218-50 sn: (b)(6).The returned lead was analyzed, passed all tests performed, and exhibited normal device characteristics.
 
Event or Problem Description
It was reported that the patients lead had high impedances.The patients leads were explanted wherein the left cervical leads distal tip were left behind.The patient was doing well postoperatively.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LINEAR
Common Device Name
STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF
Manufacturer (Section D)
BOSTON SCIENTIFIC NEUROMODULATION
25155 rye canyon loop
valencia CA 91355
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
25155 rye canyon loop
valencia CA 91355
Manufacturer Contact
erik sherburne
25155 rye canyon loop
valencia, CA 91355
7632920920
MDR Report Key15663950
Report Number3006630150-2022-05737
Device Sequence Number6385591
Product Code LGW
UDI-Device Identifier08714729767718
UDI-Public08714729767718
Combination Product (Y/N)N
Initial Reporter StateHI
Initial Reporter CountryUS
PMA/510(K) Number
P030017
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2022
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 12/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date04/17/2019
Device Model NumberSC-2158-70
Device Catalogue NumberSC-2158-70
Device Lot Number20511936
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/03/2022
Supplement Date Received by Manufacturer12/01/2022
Initial Report FDA Received Date10/24/2022
Supplement Report FDA Received Date12/22/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured04/17/2017
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age61 YR
Patient SexFemale
-
-