Model Number 7212
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/01/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Date of event: used the first date of the month of the aware date as no event date was provided.
 
Event or Problem Description
It was reported that shaft break occurred.During preparation, a 2.75mm x 12mm nc emerge balloon catheter was selected for use.However, while the balloon was loading into the wire, the shaft break outside the patient's body.The procedure was completed with a different device.There were no patient complications reported.
 
Event or Problem Description
It was reported that shaft break occurred.During preparation, a 2.75mm x 12mm nc emerge balloon catheter was selected for use.However, while the balloon was loading into the wire, the shaft break outside the patient's body.The procedure was completed with a different device.There were no patient complications reported.
 
Additional Manufacturer Narrative
B3 - date of event: used the first date of the month of the aware date as no event date was provided.Device evaluated by mfr.: returned product consisted of an nc emerge balloon catheter.The device was visually and microscopically examined.There was a separation 55.2cm from the strain relief.The separated ends were ovaled in shape indicating the device was kinked prior to separation.There was contrast in the inflation lumen and there was blood in the guidewire lumen.The balloon was tightly folded.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NC EMERGE
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer Contact
jay johnson
4100 hamline ave n
arden hills, MN 55112
6515810888
MDR Report Key15666100
Report Number2124215-2022-43283
Device Sequence Number19520272
Product Code LOX
UDI-Device Identifier08714729846383
UDI-Public08714729846383
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K141236
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/30/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/19/2023
Device Model Number7212
Device Catalogue Number7212
Device Lot Number0027866575
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/17/2022
Supplement Date Received by Manufacturer11/23/2022
Initial Report FDA Received Date10/25/2022
Supplement Report FDA Received Date11/30/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/19/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-