Model Number 120806FP
Medical Device Problem Code Material Fragmentation (1261)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/16/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Our product evaluation lab received one model 120806f catheter with stylet.The balloon latex appeared deteriorated with multiple cracks and tears evident.Both balloon windings were intact.Leakage was observed through a tear near the distal windings.The balloon latex was released from the proximal windings to check the balloon edges at the tears, which did not appear to match.Latex deterioration is a condition usually caused by age, excessive exposure to light, atmosphere, or ozone.Appears on the balloon surface as a maze of fine cracks or crazing.The condition may occur in a small area or cover the entire balloon.The stylet was kinked, and the catheter body was bent near the hub.The location of the kink on the stylet was aligned to the damage on the catheter body.A device history record review was completed and documented that the device met all specifications upon distribution.The report of balloon deterioration was confirmed on evaluation.An engineering evaluation has been initiated to assess for any manufacturing-related processes which could be correlated to the complaint.Complaint histories for all reported events are reviewed against trending control limits and any excursions above the control limits are assessed and documented as part of this monthly review.
 
Event or Problem Description
It was reported that a team of ew representatives performed an on-site visit to investigate complaints related to fogarty catheters in the vascupouch.The initial interview with hospital staff stated that catheters were stored either in central supply or the or core.The edwards team visited the locations within the hospital where catheters were received, stored, and ultimately used.During the facility walk through, it was found that the catheters were also stored in trauma or 1.Catheters were tested in locations where both the outer corrugated packaging had been removed and prior to the location of the reported failure, specifically, or core and trauma or 1.The team found evidence of xray imaging and uv sanitization being present in trauma or 1, which corresponds with other facility visit findings of high energy sources where the catheters are stored.This report is for one of the model 120806fp, lot 63852678 catheters from trauma or 1 which was noted to have a balloon that would not inflate.
 
Additional Manufacturer Narrative
An engineering evaluation was initiated to assess for any manufacturing-related processes which could be correlated to the complaint.The storage conditions for these catheters are specified in the ifu.A product risk assessment addresses balloons with fragmentations for embolectomy catheters, and a capa to address this issue is currently in its implementation phase.The capa investigation concluded that the root cause is exposure of latex to ozone, which can happen when the pouch packaged device is stored in rooms with high energy ionizing radiation sources that could generate ozone e.G.Fluoroscopy machines, x ray machines, uv lights, hvac sanitation equipment, etc.As a result, fca 90905 was voluntarily initiated instructing customers to return any product which has been stored in the same room as high energy ionizing radiation sources which emit ozone.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FOGARTY ARTERIAL EMBOLECTOMY CATHETER
Common Device Name
FOGARTY EMBOLECTOMY CATHETER
Manufacturer (Section D)
EDWARDS LIFESCIENCES, PR
state rd indus pk 402 km 1.4
anasco PR 00610
Manufacturer (Section G)
EDWARDS LIFESCIENCES, PR
state rd indus pk 402 km 1.4
anasco PR 00610
Manufacturer Contact
jessica atallah
1 edwards way
irvine, CA 92614
9492500294
MDR Report Key15680194
Report Number2015691-2022-08852
Device Sequence Number12377591
Product Code DXE
UDI-Device Identifier00690103205237
UDI-Public(01)00690103205237(17)231005(11)210706(10)63852678
Combination Product (Y/N)N
Initial Reporter StateNV
Initial Reporter CountryUS
PMA/510(K) Number
PREAMENDMENT
Number of Events Summarized1
Summary Report (Y/N)Y
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source User Facility,Company Representative
Initial Reporter Occupation Non-Healthcare Professional
Remedial Action Other,Recall
Type of Report Initial,Followup
Report Date (Section B) 11/30/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/05/2023
Device Model Number120806FP
Device Catalogue Number120806FP
Device Lot Number63852678
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/10/2022
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/14/2022
Supplement Date Received by Manufacturer11/29/2022
Initial Report FDA Received Date10/27/2022
Supplement Report FDA Received Date11/30/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/06/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-