• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION AMS INFLATABLE PENILE PROSTHESIS WITH INHIBIZONE; DEVICE IMPOTENCE MECHANICAL/HYDRAULIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION AMS INFLATABLE PENILE PROSTHESIS WITH INHIBIZONE; DEVICE IMPOTENCE MECHANICAL/HYDRAULIC Back to Search Results
Model Number 72404250
Medical Device Problem Code Insufficient Device Problem Information (3190)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/24/2018
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the patient underwent a surgical procedure to explant a penile prosthesis for unspecified reasons.
 
Additional Manufacturer Narrative
D4 product details, d6a and d6b implant and explant date, c2/d10 concomitant products, e1 initial reporter phone were updated.
 
Event or Problem Description
It was reported that the patient underwent a surgical procedure to explant a penile prosthesis for unspecified reasons.
 
Additional Manufacturer Narrative
Upon receipt at our quality assurance laboratory, this inflatable penile prosthesis (ipp) underwent a thorough analysis.The cylinders and pump were visually and microscopically examined, and leak tested; the cylinders were also pressure tested and the pump was also functionally tested.No anomalies were found with the cylinders.A fluid leak was found in the pump at the kink resistant tubing (krt) section of the strain relief junction.Based on the information available and analysis results, the leak identified in the pump could have caused or contributed to a device non conformance.
 
Event or Problem Description
It was reported that the patient underwent a surgical procedure to explant a penile prosthesis for unspecified reasons.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AMS INFLATABLE PENILE PROSTHESIS WITH INHIBIZONE
Common Device Name
DEVICE IMPOTENCE MECHANICAL/HYDRAULIC
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer Contact
alyson harris
4100 hamline avenue north
building c
saint paul, MN 55112
MDR Report Key15690975
Report Number2124215-2022-44091
Device Sequence Number6822421
Product Code FHW
UDI-Device Identifier00878953003580
UDI-Public00878953003580
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
N970012
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2022
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 01/06/2023
2 Devices were Involved in the Event: 1   2  
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Expiration Date06/07/2018
Device Model Number72404250
Device Catalogue Number72404250
Device Lot Number0137425003
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/19/2022
Supplement Date Received by Manufacturer12/06/2022
12/20/2022
Initial Report FDA Received Date10/28/2022
Supplement Report FDA Received Date12/13/2022
01/06/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/07/2016
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
RESERVOIR:UPN: 720185-01LOT: 1000033358; RESERVOIR:UPN: 720185-01LOT: 1000033358
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient SexUnknown
-
-