Model Number 451414H0
Medical Device Problem Code Device-Device Incompatibility (2919)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/04/2022
Type of Reportable Event Malfunction
Event or Problem Description
As reported, there was resistance when attaching the syringe to the hub of a 4f tempo vertebral 100cm diagnostic catheter.It was noticed that the syringe had resistance connecting to the hub during prep.Another unknown vertebral catheter was opened and worked fine.There was no reported patient injury.The device was inspected in the package prior to opening.The device was not resterilized.The device was opened in a sterile field.The user was trained to the device.The device was stored per labeling.Other procedural details were requested but are unknown, unavailable, not answered, or not applicable.The device will be returned for evaluation.
 
Additional Manufacturer Narrative
A review of the manufacturing documentation associated with lot 18092072 presented no issues during the manufacturing process that can be related to the reported event.Additional information is pending and will be submitted within 30 days upon receipt.
 
Additional Manufacturer Narrative
-after further review of additional information received the following sections have been updated accordingly: b4, d8, d9, g3, g6, h1, h2, h3, and h10 -this device is available for analysis but the engineering report is not yet available.However, it will be submitted within 30 days upon receipt.-additional information is pending and will be submitted within 30 days upon receipt.
 
Event or Problem Description
As reported, there was resistance when attaching the syringe to the hub of two 4f tempo vertebral 100cm diagnostic catheters.It was noticed that the syringe had resistance connecting to the hub during prep.Another unknown vertebral catheter was opened and worked fine.There was no reported patient injury.The device was inspected in the package prior to opening.The device was not resterilized.The device was opened in a sterile field.The user was trained to the device.The device was stored per labeling.Other procedural details were requested but are unknown, unavailable, not answered, or not applicable.The devices will be returned for evaluation.
 
Additional Manufacturer Narrative
This report is related to report # 9616099-2023-06199.After further review of additional information received the following sections have been updated accordingly: g3, g6, h1, h2, h3, h6, and h10.As reported, there was resistance when attaching the syringe to the hub of two 4f tempo vertebral 100cm diagnostic catheters.It was noticed that the syringe had resistance connecting to the hub during prep.Another unknown vertebral catheter was opened and worked fine.There was no reported patient injury.The device was inspected in the package prior to opening.The device was not resterilized.The device was opened in a sterile field.The user was trained to the device.The device was stored per labeling.Two non-sterile units of catheter cath tempo 4f ver 135 degree 100cm were received for analysis.The units were randomly identified as unit 1 and unit 2.Unit one was evaluated under complaint (b)(4) and unit 2 was evaluated under (b)(4).(b)(4).During visual inspection, no anomalies were noted on the device (brite tip/distal tip, body/shaft nor the hub).Dimensional analysis was performed to verify the correct thread outer diameter and found within specification.An attempt to connect the unit with a lab sample syringe was successfully performed and no difficulty was noted.A flushing test was performed, and no leakage or anomaly was noted.A product history record (phr) review of lot 18092072 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.(b)(4).During visual inspection, no anomalies were noted on the device (brite tip/distal tip, body/shaft nor the hub).Dimensional analysis was performed to verify the correct thread outer diameter and found within specification.An attempt to connect the unit with a lab sample syringe was successfully performed and no difficulty was noted.A flushing test was performed, and no leakage or anomaly was noted.A product history record (phr) review of lot 18092072 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.The events reported by the customer as ¿luer hub - catheters ¿ incompatibility/fit - with syringe¿ was not confirmed for either device since they were connected to a lab sample syringe with no difficulty or leaks noted.Handling factors and/or issues with the syringe may have contributed to the reported event.Users are trained to inspect for signs of damage prior to and during use.Any product with damage is not to be used.Information for safety is provided in the products labeling with the intent to make the user aware of the risks.According to the instructions for use (ifu), although not intended as a mitigation of risk, ¿treat all 4f (1.35 mm) catheters and smaller french sizes with ultimate care.The performance of these products may be impaired if not properly and cautiously handled during unpacking and preparation.¿ based on the information available and the phr review, there is no indication that the event is related to the device design or manufacturing process.Therefore, no preventative or corrective actions will be taken at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CATH TEMPO 4F VER 135 DEGREE 100CM
Common Device Name
CATHETER, INTRAVASCULAR, DIAGNOSTIC
Manufacturer (Section D)
CORDIS CORPORATION
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer (Section G)
CORDIS CORPORATION
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer Contact
karla castro
14201 nw 60 avenue
miami lakes, FL 33014
7863138372
MDR Report Key15691404
Report Number9616099-2022-06070
Device Sequence Number20667113
Product Code DQO
UDI-Device Identifier10705032007856
UDI-Public10705032007856
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K973401
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 01/11/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/28/2025
Device Model Number451414H0
Device Catalogue Number451414H0
Device Lot Number18092072
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/04/2022
Supplement Date Received by Manufacturer11/08/2022
01/06/2023
Initial Report FDA Received Date10/28/2022
Supplement Report FDA Received Date12/16/2022
01/11/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured03/03/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
UNKNOWN VERTEBRAL CATHETER
Patient SexUnknown
-
-