MEDOS INTERNATIONAL SARL DELTAFILL18 4MM X 15CM; NEUROVASCULAR EMBOLIZATION DEVICE Back to Search Results
Model Number DLF180415
Medical Device Problem Code Difficult to Advance (2920)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/01/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Product complaint # (b)(4) the purpose of this mdr submission is to report the findings of the device investigation.The embolic coil has multiple kinks.The findings meet us regulatory reporting criteria.Information regarding patient weight, height, medical history, race, and ethnicity was not reported.Procode: krd/hcg.Initial reporter phone: (b)(6).This report is being submitted pursuant to the provisions of 21 cfr, part 4.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by cerenovus, or its employees that the report constitutes an admission that the product, cerenovus, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.A supplemental report will be submitted if new facts arise which materially alter information submitted in a previous mdr report.Complaint conclusion: as reported by the field, during a pre-stent graft coil embolization, a diagnosis catheter (4f) and a prowler select plus microcatheter (product code/lot unknown) approached the inferior mesenteric artery.A deltafill18 4mm x 15cm coil (b)(4) was used for the first coil but there was an intensive resistance felt when the complaint coil was inserted into the prowler select plus, approximate 15cm.The complaint coil was re-sheathed.The microcatheter was flushed with saline and the physician attempted to re-insert again but there was a resistance.The complaint coil was replaced with another coil (same lot number) and the replacement coil was implanted without any problems.The procedure was complete with four coils implanted.The status of the patient has been stable.A continuous flush was done.The lesion was the inferior mesenteric artery.Additional information received indicated that it was not necessary to remove or replace the microcatheter.Nothing was noted to be obstructing the microcatheter.The introducer was flushed until liquid was visible at the distal end of the slit in the clear tube.The tip of the introducer firmly installed into the hub of the microcatheter and locked with the rhv during device advancement.A non-sterile deltafill18 4mm x 15cm was received contained in the decontamination pouch.Upon receiving the device, a visual inspection was performed, and no apparent damage was observed.The device was inspected under magnification, and it was found that the coil had multiple kinked conditions; it remained attached to the resistance heating (rh), and it was noted inside of the introducer.Some residues of saline solution were found inside of the introducer.The kinked conditions found in the coil precluded functional testing since the deltafill could not advance through the introducer; however, the customer complaint regarding resistance with the microcatheter was confirmed based on the appearance of the returned coil.A manufacturing record evaluation was performed for the finished device 30797229 number, and no non-conformances related to the malfunction were identified.Coil kinking is a known potential issue associated with the use of this device.The instructions for use (ifu) provide proper handling instructions for the device to prevent such issues from occurring.The coil kinking was not originally reported in the complaint; however, it is possible that a continuous flush had not been done; without an adequate flush, issues such as resistance between the coil and the microcatheter can arise.Kinking can occur during procedure handling where force may have been inadvertently applied.The complaint documented that the coil could not be advanced through from the concomitant microcatheter.It is possible that force may have inadvertently been applied during the coil advancement in an attempt to overcome the resistance encountered, which resulted in the coil kinking.A manufacturing record evaluation was performed, and no non-conformances related to the reported complaint condition were identified.It should be noted that product failure could be caused by multiple factors.The instructions for use (ifu) does contain the following recommendations: if unusual friction is noticed during advancement or retraction of the microcoil system, verify the clear tab is unlocked and pulled out from the re-sheathing tool approximately 1 in.If unusual friction is noticed during advancement or retraction of the microcoil system through the introducer, open the rhv main valve, and partially withdraw the distal end of the introducer to expose its tip within the rhv.Tighten the rhv main valve and flush the y-connector of the rhv with sterile saline and verify that fluid exits the slit in the clear portion of the introducer.After flushing, reinsert the introducer into the infusion catheter hub.If unusual friction is still noticed during advancement or retraction of the microcoil system, verify flush lines are open and properly pressurized.Then slowly withdraw the entire microcoil system and examine for damage.Replace it with a new microcoil system.If friction still exists, withdraw and examine the delivery catheter system.As part of the cerenovus quality process, all devices are manufactured, inspected, and released to approved specifications.As part of the post market surveillance program, information from this complaint is trended to identify statistical signals for consideration of further correction action.Since there was no evidence to suggest the event was related to a manufacturing or design issue, no corrective actions will be taken at this time.
 
Event or Problem Description
As reported by the field, during a pre-stent graft coil embolization, a diagnosis catheter (4f) and a prowler select plus microcatheter.Approached the inferior mesenteric artery.A deltafill18 4mm x 15cm coil (dlf180415, 30797229) was used for the first coil but there was an intensive resistance felt when the complaint coil was inserted into the prowler select plus, approximate 15cm.The complaint coil was re-sheathed.The microcatheter was flushed with saline and the physician attempted to re-insert again but there was a resistance.The complaint coil was replaced with another coil (same lot number) and the replacement coil was implanted without any problems.The procedure was complete with four coils implanted.The status of the patient has been stable.A continuous flush was done.The lesion was the inferior mesenteric artery.Additional information received indicated that it was not necessary to remove or replace the microcatheter.Nothing was noted to be obstructing the microcatheter.The introducer was flushed until liquid was visible at the distal end of the slit in the clear tube.The tip of the introducer firmly installed into the hub of the microcatheter and locked with the rhv during device advancement.Based on the product analysis of the deltafill18 4mm x 15cm, the embolic coil has multiple kinks.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DELTAFILL18 4MM X 15CM
Common Device Name
NEUROVASCULAR EMBOLIZATION DEVICE
Manufacturer (Section D)
MEDOS INTERNATIONAL SARL
chemin-blanc 38
le locle neuchatel CH-24 00
SZ  CH-2400
Manufacturer (Section G)
CODMAN & SHURTLEFF, INC. (FREMONT)
47709 fremont blvd
fremont CA 94538
Manufacturer Contact
kate karberg
31 technology dr
irvine, CA 92618
3035526892
MDR Report Key15709062
Report Number3008114965-2022-00696
Device Sequence Number6621697
Product Code KRD
UDI-Device Identifier10886704077206
UDI-Public10886704077206
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K150319
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/01/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/31/2025
Device Model NumberDLF180415
Device Catalogue NumberDLF180415
Device Lot Number30797229
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/05/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/14/2022
Initial Report FDA Received Date11/01/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/28/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
GALAXY G3 5MM X 15CM; PROWLER SELECT PLUS
Patient SexUnknown
-
-