| Model Number |
EQUINOXE, HUMERAL STEM PRIMARY, PRESS FIT 7MM |
| Medical Device Problem Codes |
Fracture (1260); Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Bone Fracture(s) (1870); Failure of Implant (1924); Periprosthetic fracture (4902)
|
| Date of Event |
09/15/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Additional information, including the product investigation, will be submitted within 30 days of receipt.
|
| |
|
Event or Problem Description
|
|
As reported, female patient had a periprosthetic fracture of the stem.Patient was revised to hrp.There was no breakage of device or surgical delay/prolongation.Patient was last known to be in stable condition following the event.X-rays and photos received.The device is not available for evaluation due to hospital policy.
|
| |
|
Additional Manufacturer Narrative
|
|
Section b5: additional information received indicates that patient's bone was broken on distal part of the stem.Section d10: concomitant products: equinoxe reverse 38mm glenosphere (cat#: 320-01-38 / serial#: (b)(6).Equinoxe reverse tray adapter plate tray +0 (cat#: 320-10-00 / serial#: (b)(6).Eq rev glenoid plate (cat#: 320-15-01 / serial#: (b)(6).Eq rev locking screw (cat#: 320-15-05 / serial#: (b)(6).Eq reverse torque defining screw kit (cat#: 320-20-00 / serial#: (b)(6).Eq rev compress screw lck cap kit, 4.5 x 22mm (cat#: 320-20-22 / serial#: (b)(6).Eq rev compress screw lck cap kit, 4.5 x 22mm (cat#: 320-20-22 / serial#: (b)(6).Eq rev compress screw lck cap kit, 4.5 x 26mm (cat#: 320-20-26 / serial#: (b)(6).Eq rev compress screw lck cap kit, 4.5 x 30mm (cat#: 320-20-30 / serial#: (b)(6).145-deg pe 38mm hum liner +0 (cat#: 320-38-00 / serial#: (b)(6).(h3) as reported, female patient had a periprosthetic fracture of the stem.Patient was revised to hrp.There was no breakage of device or surgical delay/prolongation.Patient was last known to be in stable condition following the event.X-rays and photos received.The device is not available for evaluation due to hospital policy.Upon review of the available information, there is no evidence that this is a device related problem and there is no allegation against the device.Implantation of a total joint could result pain, infection, or loosening of total joint hardware.The most likely cause of the reported event was a malunion of a fracture which was likely caused by over-reaming during implantation.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay corrected information.The following sections were corrected: b5, d2a, d2b, d8, h6: clinical code, medical device problem code, component code, investigation conclusions.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
X-ray and photos received did not pertain to this patient.
|
| |
|