| Model Number |
45887 |
| Medical Device Problem Code |
Material Twisted/Bent (2981)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
08/10/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
An end user reported an issue with a bio-stable 5f dl-55cm ir-145 kit, non-valved, with nitinol gw pg.It was reported that, approximately 10 minutes post placement of the picc line, the nurse was able to flush the device but was unable to aspirate.When the picc was placed there was no noticeable pinching of the tubing below the hub.The catheter was reported to be pinching where it connected to the hub.The patient's positioning was manipulated for 20 minutes but did not resolve the issue.It was reported that no type of securement of the hub to the patient used to prevent the hub from movement.The picc was removed and replaced.There was no report of the patient experiencing any adverse effects or harm as a result of this incident.
|
| |
|
Additional Manufacturer Narrative
|
|
It was reported that the device is not available to be returned to the manufacturer for evaluation.The results of the investigation will be sent via a follow up medwatch.Reference (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
As the reported device was not returned, angiodynamics is unable to perform a device evaluation.The customer's reported complaint description cannot be confirmed, no sample was returned. without receiving product for evaluation, we are unable to definitively determine a root cause for this incident.It was reported that the picc suture wing (hub) did not have a securement device (e.G.Statlock) in use to keep the suture wing from moving. this is potential root cause since allowing the suture wing to move freely can increase the likelihood of catheter tubing becoming kinked/pinched as it exists from the suture wing. a kinked/pinched catheter tubing in this location can affect the aspiration performance of the device.A review of the device history records was performed for the indicated lots for any deviations related to the reported failure mode of the complaint. the review confirms that the lots met all material, assembly and performance specifications; i.E.No ncr associated with reported failure mode.Labeling review: directions for use is provided with the picc device and contains the following statements: catheter stabilization: 1.Prepare stabilization site with alcohol and remove betadine, if present.2.Apply skin prep solution for enhanced adherence and skin protection.Allow skin prep solution to completely dry (10-15 seconds).3.Slide device under suture wing.Slide one suture hole over a post, then slide that post and suture wing toward opposite side until second suture hole easily fits over second post.4.Close lids over posts to secure catheter.5.Peel away paper backing and place on skin.6.Apply adhesive strip at or near insertion site.Contraindication: patients with known tape or adhesive allergies.Precaution: do not use where loss of adherence could occur, such as with a confused patient, unattended access device, diaphoretic or non-adherent skin.Precaution: minimize catheter manipulation during application and removal.Note: monitor stabilization device daily.Replace at least every seven days.A review of the angiodynamics complaint system noted no adverse trends for this complaint type and product family.This type of complaint will continue to be monitored for trends.Reference (b)(4).
|
| |
|
Search Alerts/Recalls
|