Model Number M0035473060
Medical Device Problem Code Premature Separation (4045)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/11/2022
Type of Reportable Event Serious Injury
Event or Problem Description
¿it was reported that during the procedure, the physician detached the subject coil and tried to retract the delivery wire.While retraction, it was noticed that the subject coil was not detached and came off along with the delivery wire.Physician tried to retract the delivery wire but the subject coil detached prematurely inside the patient¿s anatomy.A snare device was used to remove the subject coil.The procedure was completed successfully.No clinical consequences were reported to the patient due to this event.
 
Additional Manufacturer Narrative
H4 manufacturing date ¿ added.H3 device evaluated by mfg ¿updated.H3 summary attached - updated.D4 expiration date - added.Due to the automated manufacturing execution system (mes) there are controls in the manufacturing process to ensure the product met specifications upon release.During the visual inspection, the main coil was seen to be kinked/bent.The main coil was seen to be detached/separated.The coil delivery wire was not returned.The coil introducer sheath was not returned.Functional inspection, could not be carried out because delivery wire was not returned.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.The reported complaint was confirmed based on analysis.The device failed to meet specifications when received for complaint investigation based on the analyzed anomalies noted to the device.Additional information provided by the customer indicated that continuous flush set up and maintained throughout the procedure.No damage was noted to the packaging prior to opening, the device was confirmed to be in good condition during preparation/prior to use on the patient and was prepared as per the dfu.During analysis, it was noted that the coil delivery wire was not returned, the main coil was seen to be kinked/bent and detached separated.An assignable cause of procedural factors was assigned to the as reported/as analyzed main coil prematurely detached/separated during use, and the as reported main coil false detachment signal, and the as analyzed main coil kinked/bent as this complaint appears to be associated with a product that met stryker design and manufacturing specifications and was used in accordance with the dfu, but performance was limited due to procedural factors during use.
 
Event or Problem Description
¿it was reported that during the procedure, the physician detached the subject coil and tried to retract the delivery wire.While retraction, it was noticed that the subject coil was not detached and came off along with the delivery wire.Physician tried to retract the delivery wire but the subject coil detached prematurely inside the patient¿s anatomy.A snare device was used to remove the subject coil.The procedure was completed successfully.No clinical consequences were reported to the patient due to this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TARGET 360 SOFT 3MM X 6CM
Common Device Name
DEVICE, NEUROVASCULAR EMBOLIZATION
Manufacturer (Section D)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI  NA
Manufacturer (Section G)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI   NA
Manufacturer Contact
tara lopez
47900 bayside parkway
fremont, CA 94538
5104132500
MDR Report Key15753016
Report Number3008881809-2022-00556
Device Sequence Number2859090
Product Code HCG
UDI-Device Identifier04546540676429
UDI-Public04546540676429
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K153658
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 12/23/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/01/2025
Device Model NumberM0035473060
Device Catalogue NumberM0035473060
Device Lot Number23397465
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/26/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 10/11/2022
Supplement Date Received by Manufacturer11/28/2022
Initial Report FDA Received Date11/08/2022
Supplement Report FDA Received Date12/23/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/03/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-