| Model Number |
8888145049CP |
| Medical Device Problem Code |
Detachment of Device or Device Component (2907)
|
| Health Effect - Clinical Codes |
Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/22/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
According to the reporter, the catheter had been implanted in the patient for about 2 years and 3 months.When at home, it was found that the venous luer adapter (blue lumen) was missing from the end of the line or it fell out and patient had been admitted over the weekend due to the reported issue.The catheter was compromised to infection/air embolism/blood loss.There was no evidence of leak and it was not confirmed.There were no defects/damages found on the device and no other products were utilized.It was also stated that flushing was not performed because it was unsafe due to being unable to attach the syringe and clinell wipes was the cleaning agent used on the device.It was unsure exactly how this happened to frail patient and they were not sure if the patient had been able to remove it by himself.The catheter was not repaired because there was no repair kit available, therefore, the catheter was explanted/removed and replaced with other competitor's product to resolve the issue.The procedure was not completed.The patient was given vancomycin 1gram intravenously as intervention and a new tunneled central venous catheter (tcvc) was required to be placed wi th associated list.There was no blood loss and blood transfusion was not required.
|
| |
|
Additional Manufacturer Narrative
|
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Event or Problem Description
|
|
According to the reporter, the catheter had been implanted in the patient for about 2 years and 3 months.When at home, it was found that the venous luer adapter (blue lumen) was missing from the end of the line or it fell out and patient had been admitted over the weekend due to the reported issue.The catheter was compromised to infection/air embolism/blood loss.There was no evidence of leak and it was not confirmed.There was nothing unusual observed on the device prior to use, there were no defects/damages found on the device and there were no other products utilized.It was also stated that flushing was not performed because it was unsafe due to being unable to attach the syringe and clinell wipes was the cleaning agent used on the device.It was unsure exactly how this happened to frail patient and they were not sure if the patient had been able to remove it by himself.The patient was not responsible for any type of catheter maintenance and the wound dressing was still intact before it was found that the blue luer adapter was missing.The catheter was not repaired because there was no repair kit available, therefore, the catheter was explanted/removed and repla ced with other competitor's product to resolve the issue.It was confirmed that the patient had no infection and the procedure was not completed.The patient was given vancomycin 1gram intravenously as prophylaxis and as intervention (it was given as part of the protocol to give vancomycin cover as a prophylaxis if a dialysis catheter was been exposed/ put a risk of infection to reduce the risk of the patient becoming unwell).A new tunneled central venous catheter (tcvc) was required to be placed with associated list.There was no blood loss and blood transfusion was not required.The patient had recovered.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: b5, g3, h6 medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Additional Manufacturer Narrative
|
|
Evaluation summary: medtronic conducted an investigation based upon all information received.The device was available for evaluation.Visual inspection noted that the luer adapter was found to be cracked, leaking, or broken.It was reported that the luer adapter detached from the extension tube.The reported issue was confirmed.The product analysis noted evidence that the device was not used as intended.The manufacturing records for each device are thoroughly reviewed prior to release to ensure that it meets all medtronic quality specifications.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: g3, h3, h6 h3 evaluation summary: medtronic conducted an investigation based upon all information received.The device was not returned, but a photo was available for evaluation.Visual inspection noted the luer adapter was found to be broken.It was reported that the luer adapter was detached from the extension tube.The reported issue was confirmed.The product analysis noted evidence that the device was not used as intended.This issue may occur when excessive force is used with the the luer adapter and the extension tube.The manufacturing records for each device are thoroughly reviewed prior to release to ensure that it meets all medtronic quality specifications.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|