• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. BONE CUTTER,5.0MM X 13CM; BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. BONE CUTTER,5.0MM X 13CM; BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL Back to Search Results
Model Number BONE CUTTER,5.0MM X 13CM
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 10/19/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The contribution of the device to the reported event could not be determined as the device was not returned for evaluation.The root cause of the event could not be determined from the information available and without device evaluation.If the device becomes available for evaluation, a follow-up report will be submitted.
 
Event or Problem Description
It was reported that during an autocart ankle arthroscopy surgery the device was used for a few seconds on the bone cartilage and then started right away to show some very small metal particles to come off.Metal particles remained inside the patient.The surgery was finished successfully with a new device with the same part number.It was not necessary to switch the surgical technique or do a second surgery.
 
Additional Manufacturer Narrative
Complaint is confirmed.One unpackaged ar-8500bc batch number 10872333 was received for investigation.Visual inspection identified heavy, horizontal scratches lines along the outer diameter of the inner tube bone cutter.After removing the outer tube, more horizontal scratches were observed along the tip.Visual signs of wear were also observed proximal to the hub and along the inner and outer tube shaft.Tissue was found to be lodged in the inner and outer tubes.The observed event is most likely caused by user mechanical damage to the device, such as prying/leveraging or excessive bending forces applied during use.
 
Additional Manufacturer Narrative
Complaint is confirmed.One unpackaged ar-8500bc batch number 10872333 was received for investigation.Visual inspection identified heavy, horizontal scratches lines along the outer diameter of the inner tube bone cutter.After removing the outer tube, more horizontal scratches were observed along the tip.Visual signs of wear were also observed proximal to the hub and along the inner and outer tube shaft.Tissue was found to be lodged in the inner and outer tubes.The observed event is most likely caused by user mechanical damage to the device, such as prying/leveraging or excessive bending forces applied during use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BONE CUTTER,5.0MM X 13CM
Common Device Name
BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
vik bajnath
8009337001
MDR Report Key15758562
Report Number1220246-2022-05718
Device Sequence Number8220950
Product Code GFA
UDI-Device Identifier00888867043732
UDI-Public00888867043732
Combination Product (Y/N)N
Initial Reporter CountryPO
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 01/13/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/31/2025
Device Model NumberBONE CUTTER,5.0MM X 13CM
Device Catalogue NumberAR-8500BC
Device Lot Number10872333
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/20/2022
Supplement Date Received by Manufacturer10/20/2022
10/20/2022
Initial Report FDA Received Date11/09/2022
Supplement Report FDA Received Date12/28/2022
01/13/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured04/23/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-