Model Number NA-201SX-4021
Medical Device Problem Code Retraction Problem (1536)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/21/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Follow up response from the customer indicated that the device was handed over to the material management team.Olympus has not received the device as yet.The investigation is ongoing.A supplemental will be submitted on completion of investigation or if any additional information is available.
 
Event or Problem Description
A medwatch report was received by olympus indicating, when the surgeon proceeded to use a 21g aspiration needle during bronchoscopy, the needle would not protrude out of sheathe and so was unable to take a biopsy of lymph node twice.There was no surgical delay and no reports of patient harm associated with the event.
 
Additional Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.A review of the device history record found no deviations that could have caused or contributed to the reported issue.Based on the results of the investigation, since the device was not returned for evaluation, the root cause could not be determined.However, based on past investigations, it is likely that the needle did not protrude from the sheath because the tip of the needle tube was bent and caught on the coil sheath.The bending of the tip of the needle tube likely occurred when the tip of the needle tube was subjected to a load exceeding its resistance (e.G., hitting a hard object).The event can be detected/prevented by following the instructions for use (ifu) which state: ¿do not insert this instrument when the endoscope is angulated.This could damage the endoscope and/or this instrument.Do not insert the instrument abruptly.This could cause patient injury, such as perforation, bleeding, or mucous membrane damage.It could also damage the endoscope and/or the instrument.¿ olympus will continue to monitor field performance for this device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE USE ASPIRATION NEEDLE
Common Device Name
SINGLE USE ASPIRATION NEEDLE
Manufacturer (Section D)
AOMORI OLYMPUS CO., LTD.
2-248-1 okkonoki
kuroishi-shi, aomori 036-0 357
JA  036-0357
Manufacturer Contact
masaharu hirose
2-248-1 okkonoki
kuroishi-shi, aomori 036-0-357
JA   036-0357
426422891
MDR Report Key15784693
Report Number9614641-2022-00608
Device Sequence Number4790393
Product Code FCG
UDI-Device Identifier04953170240935
UDI-Public04953170240935
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K050503
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 02/13/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberNA-201SX-4021
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/13/2022
Supplement Date Received by Manufacturer02/01/2023
Initial Report FDA Received Date11/11/2022
Supplement Report FDA Received Date02/13/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient Age74 YR
Patient SexMale
Patient RaceWhite
-
-