MAUDE Adverse Event Report: STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY SYNCHRO2-14 SUPPORT STRAIGHT 215CM; WIRE, GUIDE, CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY SYNCHRO2-14 SUPPORT STRAIGHT 215CM; WIRE, GUIDE, CATHETER Back to Search Results
Model Number S2SPS14215
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/28/2022
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that during a neurovascular procedure, the subject guidewire fractured during use and therefore a snare was used to retrieve the fractured subject guidewire.The procedure was completed successfully.No further information is available.
 
Additional Manufacturer Narrative
The device is not available to the manufacturer.
 
Additional Manufacturer Narrative
There are controls in the manufacturing process to ensure the product met specifications upon release.Upon visual/microscopic inspection of the returned subject device, it was noted that the guidewire was returned with a catheters.The core wire distal end was observed through the distal tip dome.The guidewire was returned broken in 2 segments (5.5cm distal segment and 209.5cm proximal segment).The hydrophilic coating was hydrated and there were no anomalies noted.The proximal segment was inspected and it was noted that the nitinol tubing was broken.The core wire was stretched and the platinum wire was visibly broken (distal end of the proximal segment).The distal segment was inspected and it was noted that the nitinol tubing was broken.The core wire and platinum wire were visibly broken inside the nitinol tubing.Functional inspection was not required.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.The reported complaint was confirmed based on analysis.The device failed to meet specifications when received for complaint investigation based on the analyzed anomalies noted to the device.Additional information provided by the customer indicated that the device was confirmed to be in good condition during preparation/prior to use on the patient and was prepared as per the dfu, continuous flush was set up and maintained throughout the clinical procedure, and the patient's anatomy was moderately tortuous.The guidewire was returned broken in 2 segments (5.5cm distal segment and 209.5 cm proximal segment).At the distal end of the proximal segment, the core wire was stretched and the platinum wire was visibly broken.At the proximal end of the distal segment, the core wire and platinum wire were visibly broken inside the nitinol tubing.Based on analysis, it is probable that the guidewire experienced high tension and torsion forces during the procedure that resulted in the fracture at the distal tip.An assignable cause of procedural factors will be assigned to the as reported and as analyzed 'guidewire broken/fractured during use' as well as the as analyzed 'guidewire distal tip stretched' since these issues are associated with a product that met stryker design and manufacturing specifications and was used in accordance with the dfu but performance was limited due to procedural and/or anatomical factors during use.
 
Event or Problem Description
It was reported that during a neurovascular procedure, the subject guidewire fractured during use and therefore a snare was used to retrieve the fractured subject guidewire.The procedure was completed successfully.No further information is available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNCHRO2-14 SUPPORT STRAIGHT 215CM
Common Device Name
WIRE, GUIDE, CATHETER
Manufacturer (Section D)
STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY
4870 west 2100 south
salt lake city UT 84120
Manufacturer (Section G)
STRYKER NEUROVASCULAR-UTAH-SALT LAKE CITY
4870 west 2100 south
salt lake city UT 84120
Manufacturer Contact
tara lopez
47900 bayside parkway
fremont, CA 94538
5104132500
MDR Report Key15785326
Report Number3012931345-2022-00205
Device Sequence Number11522796
Product Code DQX
UDI-Device Identifier07613327459630
UDI-Public07613327459630
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K053268
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/20/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/11/2025
Device Model NumberS2SPS14215
Device Catalogue NumberS2SPS14215
Device Lot Number0000143124
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/31/2022
Supplement Date Received by Manufacturer01/19/2023
Initial Report FDA Received Date11/11/2022
Supplement Report FDA Received Date01/20/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/13/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-