EXACTECH, INC. EQUINOXE CAGE GLENOID S, POST AUG, RIGHT; PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED
|
Back to Search Results |
|
| Model Number |
EQUINOXE CAGE GLENOID S, POST AUG, RIGHT |
| Medical Device Problem Codes |
Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Codes |
Insufficient Information (4580); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
10/25/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Concomitants: 5789123, 300-01-11 - equinoxe, humeral stem primary, press fit 11mm; 5150165, 300-51-15 - 1.5 short fa rep plt kit; 5148477, 310-01-44 - equinoxe, humeral head short, 44mm (alpha); 5816704, 315-35-00 - glnd kwire; 5546691, 531-78-20 - shouldr gps hex pins kit.Additional information, including the product investigation, will be submitted within 30 days of receipt.
|
| |
|
Event or Problem Description
|
|
It was reported that a 60 yo female, initial right shoulder implanted (b)(6) 2019, underwent a revision procedure on (b)(6) 2022, approximately 3 years 8 months post the initial procedure.Per the surgeon, "the glenoid failed" and occurred over time.The patient was last known to be in stable condition following the event.The product is not returning due to hospital policy.No further information.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were updated/corrected: d1, h6.Mdr section codes updated/corrected: a, b, c, d, e, g.The reason for the revision reported cannot be conclusively determined but may have been the result of prosthesis wear of the cage glenoid.The wear may have been due to metal-on-metal articulation between unintended components and wear of the glenoid body due to the fracture of the center cage and subsequent boring through the glenoid body.However, the reported and investigated failures and this underlying cause cannot be confirmed because the provided image does not clearly show the state of the revised glenoid, and no relevant clinical information or radiographs were provided.Potential contributions of patient or user-related considerations to the event cannot be determined from the reported information.Should additional relevant information be obtained, a follow-up mdr will be submitted accordingly.
|
| |
|