EXACTECH, INC. LOGIC CR TIB INSERT STD, SZ 3.5, 9 MM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED,
|
Back to Search Results |
|
| Model Number |
LOGIC CR TIB INSERT STD, SZ 3.5, 9 MM |
| Medical Device Problem Code |
Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/26/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Concomitant medical products: 2822789, 02-010-03-0335, logic cr femoral cem, right, sz 3.5; 5404146, 02-012-45-3535, lgc tibial fit tray cem sz 3.5f / 3.5t; 6038382, 200-02-41, three peg patella 41mm; 5279765, 201-78-15, holding pin mini sharp point 4 pk; 5284137, 201-78-81, 3 trocar, mod.Hex 2pk; 5284161, 201-78-81, 3 trocar, mod.Hex 2pk; 5284175, 201-78-81, 3 trocar, mod.Hex 2pk; 323871, 203-96-40, (11-3661) stryker sys 6 90x25x1.27; 332364, 203-96-42, (11-3671) stryker sys 6 90x13/21x1.19; s018337, 521-78-23, threaded pin size 2.3 collared; s018357, 521-78-23, threaded pin size 2.3 collared; s010942 521-78-36, threaded pin size 5.1 collarless.Additional information, including the product investigation, will be submitted within 30 days of receipt.
|
| |
|
Event or Problem Description
|
|
It was reported that a 64 yo female patient, initial right knee implanted on (b)(6) 2019, underwent a revision procedure on (b)(6) 2022, approximately 3 years 1 month post the initial procedure due to poly wear.The patient last known to be in stable condition.No other patient/medical information reported.The product is not returning as it was disposed of by the hospital.No further information.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: the revision reported may have been the result of malalignment between the femoral and tibial components, third body wear, instability, patient-related conditions, or any combination of these possibilities, which led to wear of the polyethylene component.Additionally, a contributing factor to the reported wear may have been the result of being packaged in a non-conforming vacuum bag for more than five years.However, this cannot be confirmed as the device was not returned for evaluation and images/x-rays were unable to be obtained.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay corrected information.The following sections were corrected: b1, b2, d1, h6 - health effect - clinical code, component code, type of investigation, h7 (remove erroneous entry from initial report), h9 (remove erroneous entry from initial report) and h11.The reported event was unable to be confirmed due to limited information received from the customer.No device was returned for evaluation; further, photographs and/or radiograph images were not provided for review.A definitive root cause was unable to be determined; however, may have resulted from the result of malalignment between the femoral and tibial components, third body wear, instability, patient-related conditions, or any combination of these possibilities, which led to wear of the polyethylene component.Additionally, a contributing factor to the reported wear may have been the result of being packaged in a non-conforming vacuum bag for more than five years.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|