Model Number D402864
Medical Device Problem Code Electrical Shorting (2926)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/08/2022
Type of Reportable Event Malfunction
Event or Problem Description
This report is to advise of a short circuit found during analysis.
 
Additional Manufacturer Narrative
One duo-decapolar, bi-directional, variable radius, reflexion spiral catheter was received for evaluation.Electrode 6 displayed acceptable resistance values; however, a short circuit was detected between electrode 5 and conductor wires 1, 13 and 18.Dissection revealed no apparent wire damage or visible root cause for the short circuit detected.The device history record was reviewed to ensure that each manufacturing and inspection operation was performed.The cause of the short circuit remains unknown.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
REFLEXION¿ HD HIGH DENSITY CATHETER, 5 F LOOP BI-DIRECTIONAL, 99 CM LENGTH, SYMM
Common Device Name
CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING
Manufacturer (Section D)
ST. JUDE MEDICAL
14901 deveau place
minnetonka MN 55345
Manufacturer (Section G)
ST. JUDE MEDICAL
14901 deveau place
minnetonka MN 55345
Manufacturer Contact
janna parks
5050 nathan lane north
plymouth, MN 55442
6517565400
MDR Report Key15794898
Report Number2182269-2022-00058
Device Sequence Number4675009
Product Code DRF
UDI-Device Identifier05414734217262
UDI-Public05414734217262
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K080179
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/14/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/28/2025
Device Model NumberD402864
Device Catalogue NumberD402864
Device Lot Number8381894
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/11/2022
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/31/2022
Initial Report FDA Received Date11/14/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/14/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1